Allen-Bradley 1769-OW16 CompactLogix Relay Output Module
The Allen-Bradley 1769-OW16, also cataloged as the 1769-OW16 Relay Output Module, operates as a dedicated hardware component for switching discrete AC and DC load circuits within CompactLogix and MicroLogix 1500 system platforms.
Hardware Specifications
| Parameter | Specification |
|---|---|
| Model | 1769-OW16 |
| Brand | Allen-Bradley / Rockwell Automation |
| Origin | Malaysia |
| Weight | 0.3 kg (0.66 lbs) |
| Dimensions | 52.5 mm x 118 mm x 87 mm |
| Operating Temp | 0 to 60 deg C |
| Power Consumption | 4.75 W max heat dissipation |
| Bus Current Draw | 205 mA at 5 VDC, 180 mA at 24 VDC |
| Operating Voltage Range | 5 to 265 VAC / 5 to 125 VDC |
| Number of Outputs | 16 normally open (2 isolated groups of 8) |
| Max Current per Point | 2.5 A |
| Max Current per Common | 10 A |
| Max Current per Module | 20 A |
| Minimum Load Current | 10 mA at 5 VDC |
| Signal Delay (Resistive) | 10 ms max (On and Off) |
| Isolation Voltage | 1836 VAC for 1 s or 2596 VDC for 1 s |
| Wire Size | 22 to 14 AWG solid, 22 to 16 AWG stranded |
| Power Supply Distance | 8 modules |
Backplane Bus & Deterministic Network Execution
The module interfaces directly through the 1769 Compact I/O backplane bus communication velocity framework, establishing deterministic timing execution for output commands generated by the local controller. Internal ASIC logic manages signal decoding across the local bus, transferring command frames to the dual-group output drivers while continuously enforcing channel-to-backplane galvanic isolation. This backplane architecture maintains strict execution stability during high-density I/O bus scaling, ensuring that signal propagation delay remains under 10 ms even under maximum backplane bus current draw limits (205 mA at 5 VDC and 180 mA at 24 VDC). Firmware flash compatibility ensures uniform state handshaking between the module registers and the master processor across demanding scan cycles.
Frequently Asked Questions
Q: What limits apply to the power supply distance rating when installing this module on a 1769 backplane?
A: You must mount the module within 8 bank locations of the system power supply. Exceeding an 8-module distance rating causes voltage drops across the backplane bus logic lines, leading to backplane communication faults or module initialization failures.
Q: Can you mix AC and DC voltages on the same 1769-OW16 module?
A: Yes. The 16 outputs divide into two individually isolated groups of 8 points. You can apply AC operating voltages to one group common and DC operating voltages to the second group common without cross-channel interference, provided you do not exceed 2.5 A per point or 10 A per common.
Field Installation Guidelines
Mount the unit directly onto an IEC standard DIN rail or secure it to a panel backplate using M4 screws. Always verify that the power supply distance rating remains within 8 modules of the system power source before locking the bus levers.
When landing conductors, strip insulation back to specified lengths and use copper wiring rated for at least 90 deg C. Secure solid (22 to 14 AWG) or stranded (22 to 16 AWG) leads into the screw terminal block, applying a strict torque limit of 0.68 N m (6 lb in).
Ensure field wiring runs maintain strict physical separation from high-voltage motor feeds and variable frequency drive outputs. Earth ground connections must terminate directly at the enclosure ground bus using low-impedance grounding straps to preserve channel-to-backplane isolation integrity.
| Quick Quotes | Receive price & availability FAST from our dedicated customer service team. |
|---|---|
| Delivery | Expedited, Freight, And International Shipping Available. |
| Condition | 100% New with Original Package |
| Payment | We accept American Express, Discover, MasterCard, PayPal, and Visa. Our site is secured by RapidSSL. |
| Shipping Port | ShangHai, Xiamen |
| Warranty | 12 Months |
| Q: Is Our Pricing Competitive? |
| A: Yes, we collaborate with over 50 countries worldwide. As a top supplier in China, we offer significant discounts based on market trends. |
| Q: What Is the Warranty Period? |
| A: All our new and original products come with a standard one-year warranty. |
| Q: What Payment Methods Do We Accept? |
| A: We require 100% T/T (Telegraphic Transfer) payment before shipping. For items with a lead time, a 30% deposit is needed upfront, and the remaining 70% is due before shipping. If you have a representative in China, you can arrange an RMB transfer through them. |
| Q: What Shipping Methods Do We Use? |
| A: We primarily use FedEx, DHL, UPS, and BRE for shipping. If you have an account with any of these carriers, you can handle shipping directly. We also offer free shipping to China-based freight forwarders. |
| Q: What Is Our Delivery Time? |
| A: Delivery usually takes 1-3 days after receiving the initial payment. For items with a lead time, shipping will occur according to the specified schedule. |
| Q: How Do We Package the Goods? |
| A: We ensure safe packaging with multiple layers of protection. Products are first placed in their original boxes and sealed with labels. A layer of bubble wrap is then added for collision protection during transit. Finally, the items are packed securely in durable boxes. |
| Q: How Can Customers Contact Us and Request a Quote? |
| A: You can reach out to us via email, WhatsApp, WeChat, Skype, or your preferred communication platform. Contact us with your needs, and we'll provide a prompt, customized quote. |