{"product_id":"alp111-s00-s1-yokogawa-profibus-dp-module","title":"ALP111-S00 S1 Yokogawa PROFIBUS-DP Module","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eALP111-S00 S1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-performance\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePROFIBUS-DP master communication module\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edesigned for the Yokogawa Electric Corporation\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCENTUM VP\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCS 3000\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eField Control Stations (FCS).\u003c\/p\u003e\n\u003cp\u003eThis module provides a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003erobust gateway\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ebetween the Yokogawa DCS and decentralized field devices—such as motor starters, variable frequency drives (VFDs), and remote I\/O manifolds—via the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFIO (Field network I\/O) bus\u003c\/strong\u003e. It ensures deterministic, high-speed communication and seamless integration of third-party PROFIBUS-compliant hardware into the CENTUM engineering environment.\u003c\/p\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e“S1”\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ehardware revision enhances reliability for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003econtinuous 24\/7 process operations\u003c\/strong\u003e, while its compact, precision-engineered Japanese design makes it ideal for modernizing plant-floor connectivity and supporting comprehensive asset management.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Number\u003c\/td\u003e\n\u003ctd\u003eALP111\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSuffix Code\u003c\/td\u003e\n\u003ctd\u003e-S00 S1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtocol\u003c\/td\u003e\n\u003ctd\u003ePROFIBUS-DP (Decentralized Periphery)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterface Role\u003c\/td\u003e\n\u003ctd\u003ePROFIBUS-DP Master\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransmission Speed\u003c\/td\u003e\n\u003ctd\u003e9.6 kbps to 12 Mbps (auto-sensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. Connected Slaves\u003c\/td\u003e\n\u003ctd\u003eUp to 125 slaves (system dependent)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Port\u003c\/td\u003e\n\u003ctd\u003e9-pin D-sub (female)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInternal Isolation\u003c\/td\u003e\n\u003ctd\u003e1500 V AC between communication and system\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W × H × D)\u003c\/td\u003e\n\u003ctd\u003e5 × 13 × 15 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e0.6 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eApplication and System Integration\u003c\/h3\u003e\n\u003cp\u003eThe ALP111-S00 S1 is installed in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFIO node units\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(e.g., ANB10, ANB11) and connects to the Field Control Unit (FCU) via the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eESB bus\u003c\/strong\u003e. It is widely deployed in:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eWater and wastewater treatment facilities\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOil and gas process plants\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eManufacturing and industrial automation systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eIt consolidates data from PROFIBUS field devices into a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eunified CENTUM VP control architecture\u003c\/strong\u003e, supporting reliable monitoring and control.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eProfessional FAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the ALP111-S00 S1 support redundancy?\u003c\/strong\u003e\u003cbr\u003eYes. For high-availability applications, two modules can be installed in adjacent slots of a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eredundant node unit\u003c\/strong\u003e, providing a dual-redundant PROFIBUS master configuration.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs the GSD file required for configuration?\u003c\/strong\u003e\u003cbr\u003eYes. While the ALP111 functions as the master,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGSD (General Station Description) files\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efrom each slave device must be imported into the Yokogawa Builder software for proper communication setup.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this module be used with PROFIBUS-PA devices?\u003c\/strong\u003e\u003cbr\u003eThe ALP111-S00 S1 is a DP master. To connect\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePROFIBUS-PA instruments\u003c\/strong\u003e, a DP\/PA segment coupler or link is required between this module and the PA field devices.\u003c\/p\u003e","brand":"YOKOGAWA","offers":[{"title":"Default Title","offer_id":51799346741560,"sku":"ALP111-S00 S1","price":188.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/ALP111-S00_S11.jpg?v=1771037170","url":"https:\/\/www.automodulexpert.com\/products\/alp111-s00-s1-yokogawa-profibus-dp-module","provider":"AutoModuleXpert Ltd.","version":"1.0","type":"link"}