{"product_id":"amn51-yokogawa-communication-card-nest-centum-cs-vp","title":"AMN51  Yokogawa Communication Card Nest CENTUM CS\/VP","description":"\u003ch2\u003e\u003cstrong\u003eProduct Description\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAMN51\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-integrity\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ecommunication module nest\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edesigned for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYokogawa Distributed Control Systems (DCS)\u003c\/strong\u003e. It provides a secure and organized platform for network cards, offering\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ephysical slots, backplane connectivity, and stable power distribution\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto ensure seamless data exchange between Field Control Stations (FCS) and Node Interface Units (NIU).\u003c\/p\u003e\n\u003cp\u003eBuilt for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003emission-critical industrial environments\u003c\/strong\u003e, the AMN51 protects sensitive communications from electromagnetic interference, supports flexible installation in FCS or expansion racks, and centralizes communication hardware to maximize reliability and uptime.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003e\u003cstrong\u003eItem\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Identification\u003c\/td\u003e\n\u003ctd\u003eAMN51\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrimary Function\u003c\/td\u003e\n\u003ctd\u003eCommunication module nest\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Voltage\u003c\/td\u003e\n\u003ctd\u003e5.0 V DC (internal logic power)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Source\u003c\/td\u003e\n\u003ctd\u003eProvided via AND50, ANS50, AND20, ANS20 NIU, or PFCS\/PFCD backplane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Options\u003c\/td\u003e\n\u003ctd\u003eNIU integration, I\/O expansion rack, PFCS\/PFCD station\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Support\u003c\/td\u003e\n\u003ctd\u003eYokogawa proprietary and standard industrial network cards\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackplane Interface\u003c\/td\u003e\n\u003ctd\u003eHigh-speed internal bus for data throughput\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W × D × H)\u003c\/td\u003e\n\u003ctd\u003e137.5 mm × 225 mm × 254 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2.5 kg \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndustrial Compliance\u003c\/td\u003e\n\u003ctd\u003eContinuous operation in mission-critical DCS environments\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch2\u003e\u003cstrong\u003eApplication Scenarios\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNetwork Expansion\u003c\/strong\u003e\u003cbr\u003eAdding auxiliary communication protocols (Modbus, Ethernet\/IP, etc.) to PFCS or PFCD stations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDistributed I\/O Communication\u003c\/strong\u003e\u003cbr\u003eServing as a communication hub within Node Interface Units to connect remote I\/O points to the central controller.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSystem Redundancy\u003c\/strong\u003e\u003cbr\u003eHousing redundant communication modules to ensure uninterrupted data flow in high-safety process industries.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003e\u003cstrong\u003eProduct FAQ\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the AMN51 provide its own power?\u003c\/strong\u003e\u003cbr\u003eA: No. It draws the required\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5 V DC\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efrom the host Node Interface Unit or Field Control Station backplane.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Which communication cards are compatible?\u003c\/strong\u003e\u003cbr\u003eA: The AMN51 accepts\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003estandard Yokogawa communication modules\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eused in CENTUM series systems for interfacing with fieldbus protocols and supervisory networks.\u003c\/p\u003e","brand":"YOKOGAWA","offers":[{"title":"Default Title","offer_id":51718368493880,"sku":"AMN51","price":188.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/AMN512.jpg?v=1770345462","url":"https:\/\/www.automodulexpert.com\/products\/amn51-yokogawa-communication-card-nest-centum-cs-vp","provider":"AutoModuleXpert Ltd.","version":"1.0","type":"link"}