{"product_id":"analog-input-module-card-emerson-1c31116g04-ovation","title":"Analog Input Module Card | Emerson 1C31116G04 Ovation","description":"\u003ch2\u003eEmerson 1C31116G04 Ovation Analog Input Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eEmerson 1C31116G04\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e1C31116G04\u003c\/strong\u003e Analog Input Module, operates as a dedicated hardware component for field signal digitization and data acquisition within Ovation DCS platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e1C31116G04\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eEmerson\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.45 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard Ovation I\/O card dimensions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 deg C to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eStandard backplane power load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCategory\u003c\/td\u003e\n\u003ctd\u003eAnalog Input Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Input Type\u003c\/td\u003e\n\u003ctd\u003eAnalog field current \/ voltage loops\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBus Interface\u003c\/td\u003e\n\u003ctd\u003eOvation Controller Backplane Bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Conversion\u003c\/td\u003e\n\u003ctd\u003eHigh-resolution analog-to-digital processing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e4-20 mA HART Loop Protocol \u0026amp; Galvanic Isolation\u003c\/h3\u003e\n\u003cp\u003eThe module processes incoming analog field variables through precision signal-conditioning circuitry designed to reject common-mode line interference. It routes digitizing channels across a high-density backplane interface while supporting standard 4-20 mA current loop configurations. The internal electrical design utilizes dielectric galvanic isolation barriers between the field-side loop connections and the system controller bus, preventing ground loops and protecting central logic units from field-induced electrical noise.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How does the 1C31116G04 seat within the Ovation hardware assembly?\u003c\/p\u003e\n\u003cp\u003eA: The module installs directly into standard Ovation I\/O base chassis card slots, interfacing electrically via the dual-redundant backplane bus connectors.\u003c\/p\u003e\n\u003cp\u003eQ: What mechanisms protect the module against field wiring electrical noise?\u003c\/p\u003e\n\u003cp\u003eA: Onboard filtering components combined with galvanic dielectric barriers isolate individual input channels from backplane logic circuitry, suppressing ground potential differences.\u003c\/p\u003e\n\u003cp\u003eQ: Is field power distributed to transmitters through the module card edge?\u003c\/p\u003e\n\u003cp\u003eA: Depending on system baseboard jumpers and terminal block wiring, field loops draw power either directly from local transmitter supplies or through integrated auxiliary power rails routed via the baseboard interface.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eFollow these sequential physical installation steps when integrating the module:\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eTurn off auxiliary power sources feeding the target terminal block prior to module insertion.\u003c\/li\u003e\n\u003cli\u003eAlign the 1C31116G04 circuit card edges with the card guide tracks on the designated Ovation chassis slot.\u003c\/li\u003e\n\u003cli\u003eSlide the card backward until the backplane multi-pin connectors mate fully with the base board header.\u003c\/li\u003e\n\u003cli\u003eEngage upper and lower mechanical retention levers to lock the module securely against vibration.\u003c\/li\u003e\n\u003cli\u003eVerify that field wiring shields land on the dedicated enclosure earth grounding bar rather than signal return terminals.\u003c\/li\u003e\n\u003cli\u003eRe-energize loop power and inspect the front panel LED indicators to confirm bus communication and channel scanning activity.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"OVATION","offers":[{"title":"Default Title","offer_id":51216231334200,"sku":"1C31116G04","price":190.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/1C31116G042.jpg?v=1759977358","url":"https:\/\/www.automodulexpert.com\/products\/analog-input-module-card-emerson-1c31116g04-ovation","provider":"AutoModuleXpert Ltd.","version":"1.0","type":"link"}