{"product_id":"analog-input-module-general-electric-ic695alg616-ea","title":"Analog Input Module General Electric IC695ALG616-EA","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC695ALG616-EA\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-density\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eanalog input module\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edesigned for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePACSystems RX3i\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eseries. This module provides\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e16 single-ended\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eor\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8 differential analog input channels\u003c\/strong\u003e, allowing for the conversion of external sensor signals into digital data for the CPU. It supports a wide array of voltage and current ranges, making it ideal for applications such as pressure, temperature, and flow monitoring in complex industrial processes.\u003c\/p\u003e\n\u003cp\u003eWe supply this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New original\u003c\/strong\u003e, manufactured in the USA to meet strict global automation standards.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChannels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16 Single-Ended or 8 Differential\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNon-isolated Analog Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16-bit A\/D Converter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.5 cm x 13.3 cm x 13.6 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.22 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBackplane Support\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUniversal Backplane (PCI Bus)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Density Monitoring\u003c\/strong\u003e\u003cbr\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e16-channel\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003earchitecture allows you to monitor a wide range of sensors while occupying only a single slot on the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eRX3i backplane\u003c\/strong\u003e, which maximizes cabinet space efficiency.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlexible Software Configuration\u003c\/strong\u003e\u003cbr\u003eInput ranges and scaling parameters are configured entirely through the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePAC Machine Edition\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esoftware, eliminating the need for physical jumpers or manual adjustments.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOn-Board Diagnostics\u003c\/strong\u003e\u003cbr\u003eThe module continuously monitors for conditions like\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eopen circuits\u003c\/strong\u003e,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eunder-range\/over-range\u003c\/strong\u003e, and\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003einternal faults\u003c\/strong\u003e, providing immediate feedback to the CPU for faster troubleshooting.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Speed Conversion\u003c\/strong\u003e\u003cbr\u003eEquipped with a dedicated\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e16-bit A\/D converter\u003c\/strong\u003e, the module offers\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003efast and precise data sampling\u003c\/strong\u003e, which is essential for applications requiring real-time feedback, such as closed-loop control.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRobust Noise Rejection\u003c\/strong\u003e\u003cbr\u003eAdvanced\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003edigital filtering\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003etechnology helps reduce the effects of electrical noise and signal interference, ensuring stable and reliable data readings in electrically noisy industrial environments.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the difference between the -EA version and the standard module?\u003c\/strong\u003e\u003cbr\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e\"-EA\"\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esuffix indicates a specific hardware revision or a regional manufacturing designation. This version is fully functionally compatible and backward compatible with the standard\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC695ALG616\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eseries.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this module provide channel-to-channel isolation?\u003c\/strong\u003e\u003cbr\u003eNo, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC695ALG616-EA\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003enon-isolated\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emodule. All channels share a common return. If your application requires isolation between inputs, you should select a module from the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eisolated series\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I mix voltage and current inputs on the same module?\u003c\/strong\u003e\u003cbr\u003eYes, each channel can be configured independently through software to accept either\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003evoltage\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eor\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ecurrent\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esignals, as long as the total channel count stays within the module's limits.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs a specific terminal block required for installation?\u003c\/strong\u003e\u003cbr\u003eYes, you must use a compatible\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eRX3i terminal block\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(sold separately) for field wiring. It is recommended to use\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eshielded twisted-pair cabling\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto maintain signal integrity and reduce the effects of noise.\u003c\/p\u003e","brand":"GE FANUC","offers":[{"title":"Default Title","offer_id":52186176422200,"sku":"IC695ALG616-EA","price":220.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/IC695ALG616-EA_482f7231-c9d8-4a16-957b-292c94af358b.jpg?v=1776130633","url":"https:\/\/www.automodulexpert.com\/products\/analog-input-module-general-electric-ic695alg616-ea","provider":"AutoModuleXpert Ltd.","version":"1.0","type":"link"}