{"product_id":"analog-input-module-yokogawa-nfai141-s01","title":"Analog Input Module Yokogawa NFAI141-S01","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eNFAI141-S01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-performance\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eanalog input module\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eengineered for demanding process automation applications. It provides precise data acquisition and supports multiple input signal types, including\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e0–10 V voltage signals\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e0–20 mA current loops\u003c\/strong\u003e, making it a versatile interface between field instrumentation and\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYokogawa DCS control architectures\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eDesigned for high-precision industrial measurement, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eNFAI141-S01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edelivers an accuracy of\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e±0.05% of reading\u003c\/strong\u003e, making it suitable for critical process control loops where measurement stability is essential. The module incorporates\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eprogrammable gain amplification and selectable filtering\u003c\/strong\u003e, enabling engineers to optimize signal conditioning and effectively suppress electrical noise in harsh industrial environments.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Identification\u003c\/td\u003e\n\u003ctd\u003eNFAI141-S01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDevice Function\u003c\/td\u003e\n\u003ctd\u003eAnalog Input Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Input Range\u003c\/td\u003e\n\u003ctd\u003e0–10 V (0.01 V minimum resolution)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Input Range\u003c\/td\u003e\n\u003ctd\u003e0–20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±0.05% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSampling Rate\u003c\/td\u003e\n\u003ctd\u003eUp to 10 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Conditioning\u003c\/td\u003e\n\u003ctd\u003eProgrammable gain and selectable filtering\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Output\u003c\/td\u003e\n\u003ctd\u003eAnalog, digital, and serial data transmission\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDesign Type\u003c\/td\u003e\n\u003ctd\u003eCompact high-density cabinet mounting module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eApplication\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePrecision Process Monitoring:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIntegrates pressure, flow, and level transmitters into CENTUM control systems.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Speed Data Acquisition:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe 10 kHz sampling rate enables accurate capture of fast-changing process signals.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNoise Reduction Applications:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProgrammable filtering helps stabilize signals from long-distance field wiring.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTest and Measurement Systems:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSuitable for dynamic process analysis and advanced automation diagnostics.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical FAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the 10 kHz sampling rate benefit my process?\u003c\/strong\u003e\u003cbr\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e10 kHz sampling rate\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eenables high-resolution monitoring of rapidly changing process variables, reduces signal aliasing, and ensures accurate transient signal capture for control system processing.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs the module compatible with 4–20 mA HART transmitters?\u003c\/strong\u003e\u003cbr\u003eYes. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e0–20 mA input range\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efully supports standard\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e4–20 mA HART instrumentation signals\u003c\/strong\u003e, maintaining high measurement accuracy even when digital HART communication is superimposed on the analog loop.\u003c\/p\u003e","brand":"YOKOGAWA","offers":[{"title":"Default Title","offer_id":51859561283896,"sku":"NFAI141-S01","price":188.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/NFAI141-S01.jpg?v=1772762249","url":"https:\/\/www.automodulexpert.com\/products\/analog-input-module-yokogawa-nfai141-s01","provider":"AutoModuleXpert Ltd.","version":"1.0","type":"link"}