{"product_id":"analog-termination-module-ge-ds200ctbag1a","title":"Analog Termination Module GE DS200CTBAG1A","description":"\u003cp\u003eConfigured for signal conditioning and termination in Mark V LM turbine control systems, the \u003cstrong\u003eGE DS200CTBAG1A\u003c\/strong\u003e (\u003cstrong\u003eDS200CTBAG1A\u003c\/strong\u003e Analog Termination Module) provides direct physical\/electrical execution. This printed circuit board acts as a central interface for the system’s common data processor, managing incoming and outgoing analog signals to ensure precise turbine control.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eDS200CTBAG1A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGeneral Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.0 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e16 cm x 16 cm x 12 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-28 to 55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eLogic level dependent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eMark V LM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e4-20 mA HART Loop Protocol and Signal Conditioning\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eDS200CTBAG1A\u003c\/strong\u003e module is specifically engineered to handle analog input and output signals, primarily functioning within the 4-20 mA range. It provides essential signal conditioning for shaft voltage and shaft current telemetry, which are critical for monitoring mechanical health in turbine assemblies. The board integrates seamlessly with IONET and COREBUS communication interfaces, ensuring data is relayed accurately between the R5 core and other system components such as the TCCA or QTBA boards. A dedicated bypass relay is embedded in the surface assembly, allowing COREBUS communication to remain active even in the event of a localized power loss to the CTBA board.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Is the DS200CTBAG1A compatible with non-Mark V turbine systems?\u003c\/p\u003e\n\u003cp\u003eA: No, this module is purpose-built for the GE Speedtronic Mark V LM turbine control architecture and is not electrically compatible with other Mark series control platforms.\u003c\/p\u003e\n\u003cp\u003eQ: What is the purpose of the RS-232 9-pin d-shell port on the board?\u003c\/p\u003e\n\u003cp\u003eA: The onboard serial port is provided to facilitate TIMN diagnostic communication, allowing technicians to monitor system signals and status via an external workstation.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eEnsure the Mark V control rack is de-energized and follows proper lockout\/tagout procedures before handling the module.\u003c\/li\u003e\n\u003cli\u003eAlign the board with the R5 core mounting slots; use the factory-drilled holes in the corners for secure installation using appropriate mounting hardware.\u003c\/li\u003e\n\u003cli\u003eVerify that all jumper switches (BJ1-BJ14) are configured according to the specific requirements of the connected field sensors (e.g., mA input NEG to DCOM).\u003c\/li\u003e\n\u003cli\u003eConnect the signal cables to the appropriate terminal strips (e.g., JAA, JBB, JPD); ensure that termination resistors are installed on any unused COREBUS connections (JAI\/JAJ) to prevent signal reflection.\u003c\/li\u003e\n\u003cli\u003eInspect the conductive ringed mounting holes to ensure they provide a proper path to chassis ground for protection against surface voltages.\u003c\/li\u003e\n\u003cli\u003eOnce installed, verify that the bypass relay is operational and that the COREBUS link is established before bringing the system to a high-power state.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"GE FANUC","offers":[{"title":"Default Title","offer_id":52592688988472,"sku":"DS200CTBAG1A","price":220.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/DS200CTBAG1A1.jpg?v=1782892597","url":"https:\/\/www.automodulexpert.com\/products\/analog-termination-module-ge-ds200ctbag1a","provider":"AutoModuleXpert Ltd.","version":"1.0","type":"link"}