This ANB10D-421/CU2N/NDEL Node Interface Units was manufactured by YOKOGAWA, In Stock, 100% Guaranteed Brand New and Authentic. Link to More Information

 
Manufacturer:
YOKOGAWA
Part Number:
ANB10D-421/CU2N/NDEL
Product type:
Country of Origin:
Japan
Condition:
New With Original Package
Shipping Port:
ShangHai, Xiamen
Warranty:
12 Months
 

Yokogawa ANB10D-421 CENTUM Node Interface Unit

The Yokogawa ANB10D-421/CU2N/NDEL, also cataloged as the ANB10D-421 Node Interface Unit, operates as a dedicated hardware component for dual-redundant data communication execution within Yokogawa CENTUM platforms.

Suffix Breakdown & Model Matrix

Option Code Description Functional Assignment
/CU2N Connector Unit Dual-redundant Vnet/IP bus interface connector
/NDEL Node Option Standard node mounting without explosion-proof barrier options

Hardware Specifications

Parameter Specification
Model ANB10D-421/CU2N/NDEL
Brand Yokogawa
Origin Japan
Weight 1.2 kg
Dimensions Standard CENTUM node unit footprint
Operating Temp 0 to 50 deg C
Power Consumption 15 W
System Interface Ethernet, coaxial connector
Network Topology Dual-redundant Vnet/IP bus

Dual-Redundant Vnet/IP Bus Communication & DCS Interfacing

The module hosts dual coaxial and Ethernet physical interfaces to support deterministic Vnet/IP communication between central control stations and remote I/O nests. Internal channel-to-channel isolation safeguards backplane data pathways against common-mode noise propagation and voltage surges originating from long field network runs. Integrated diagnostic circuitry continuously checks transmission line signal integrity across both primary and secondary communication paths. When line attenuation or open-circuit conditions occur on the primary channel, the unit executes an immediate hardware failover to the secondary bus without interrupting real-time DCS process control loops or cyclic data polling.

Frequently Asked Questions

Q: How does the module maintain network communication during a bus line physical failure?

A: The onboard dual-redundant communication controller monitors signal levels on both active and standby channels simultaneously. If link loss occurs on the primary bus, the hardware switches traffic to the secondary channel within microseconds to prevent node offline timeouts.

Q: What power budget considerations apply when installing the ANB10D-421/CU2N/NDEL in a control cabinet?

A: The unit consumes 15 W at steady-state operation. Ensure cabinet power distribution units account for this heat output and current draw alongside connected node supply units.

Field Installation Guidelines

Ensure main power feed supplies to the enclosure node rack are de-energized before mounting the unit. Align the module base housing with the cabinet mounting rail slots and tighten retaining fasteners securely to maintain chassis grounding integrity.

For bus network installation and wiring:

  1. Connect primary and secondary coaxial or Ethernet cables to the designated /CU2N interface connectors.
  2. Maintain specified minimum bending radii for network cables during bundle routing inside cabinet channels to prevent signal reflection.
  3. Verify that coaxial cable shield connectors link directly to system ground at the bus termination points; do not permit floating shield connections.
  4. Separate network communication lines from high-current AC power wiring runs by at least 200 mm to avoid inductive coupling.
Quick Quotes Receive price & availability FAST from our dedicated customer service team.
Delivery Expedited, Freight, And International Shipping Available.
Condition 100% New with Original Package
Payment We accept American Express, Discover, MasterCard, PayPal, and Visa. Our site is secured by RapidSSL.
Shipping Port ShangHai, Xiamen
Warranty 12 Months
Q: Is Our Pricing Competitive?
A: Yes, we collaborate with over 50 countries worldwide. As a top supplier in China, we offer significant discounts based on market trends.
Q: What Is the Warranty Period?
A: All our new and original products come with a standard one-year warranty.
Q: What Payment Methods Do We Accept?
A: We require 100% T/T (Telegraphic Transfer) payment before shipping. For items with a lead time, a 30% deposit is needed upfront, and the remaining 70% is due before shipping. If you have a representative in China, you can arrange an RMB transfer through them.
Q: What Shipping Methods Do We Use?
A: We primarily use FedEx, DHL, UPS, and BRE for shipping. If you have an account with any of these carriers, you can handle shipping directly. We also offer free shipping to China-based freight forwarders.
Q: What Is Our Delivery Time?
A: Delivery usually takes 1-3 days after receiving the initial payment. For items with a lead time, shipping will occur according to the specified schedule.
Q: How Do We Package the Goods?
A: We ensure safe packaging with multiple layers of protection. Products are first placed in their original boxes and sealed with labels. A layer of bubble wrap is then added for collision protection during transit. Finally, the items are packed securely in durable boxes.
Q: How Can Customers Contact Us and Request a Quote?
A: You can reach out to us via email, WhatsApp, WeChat, Skype, or your preferred communication platform. Contact us with your needs, and we'll provide a prompt, customized quote.
 

Recently Viewed

Express Shipping icon
Express Shipping
Rapid delivery for your urgent requirements.
Large stock icon
Extensive Inventory
Large stock for immediate dispatch.
Quality Assurance Icon
Quality Assurance
Authentic, top-grade PLC & DCS components.
Global Service icon
Global Service
Supporting clients worldwide with dependable service.