{"product_id":"arm55c-relay-board-yokogawa","title":"ARM55C Relay Board Yokogawa","description":"\u003ch2\u003eTechnical Overview\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eARM55C\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-density\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003erelay terminal board\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ewithin the Yokogawa\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFAST\/TOOLS and I\/O interface\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efamily. Designed for integration with\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCENTUM VP\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCENTUM CS 3000\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esystems, it provides a reliable interface for controlling\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ehigh-power field devices\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eusing low-level control signals.\u003c\/p\u003e\n\u003cp\u003eWith\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e32 independent dry contact outputs\u003c\/strong\u003e, the ARM55C electrically isolates control electronics from field-side noise and surge conditions, ensuring stable operation in demanding process automation environments.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eDetailed Specifications\u003c\/h2\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eDigital relay output terminal board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Designation\u003c\/td\u003e\n\u003ctd\u003eARM55C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Channels\u003c\/td\u003e\n\u003ctd\u003e32 dry contact outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Type\u003c\/td\u003e\n\u003ctd\u003eM3.5 screw terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eMax. 26 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 °C to +55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W × H × D)\u003c\/td\u003e\n\u003ctd\u003e279.5 × 25 × 298.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e2.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReliability Features\u003c\/td\u003e\n\u003ctd\u003eDiagnostics support, redundant power compatible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch2\u003eApplication\u003c\/h2\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eSolenoid valve control\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMotor starters and contactors (via interposing relays)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAlarm annunciators\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAny application requiring\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003edry-contact isolation\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ebetween control logic and field devices\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eFunctional \u0026amp; Maintenance Characteristics\u003c\/h2\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eSupports\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ehot-swapping\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor maintenance without process interruption\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBuilt-in diagnostics assist in early fault detection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e19-inch rack–compatible for standard industrial cabinets\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDesigned for long relay life and high switching reliability\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnical FAQ\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eWhat types of loads can the ARM55C control?\u003c\/strong\u003e\u003cbr\u003eThe dry contact outputs are suitable for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003esolenoid valves, motor starters, annunciators, and interposing relays\u003c\/strong\u003e, where galvanic isolation is required.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the ARM55C support redundant power supplies?\u003c\/strong\u003e\u003cbr\u003eYes. The board is compatible with\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003edual-redundant power configurations\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto maintain output availability during a single power source failure.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the ARM55C manage high wiring density?\u003c\/strong\u003e\u003cbr\u003eThe use of\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eM3.5 screw terminals\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprovides secure wiring while accommodating high channel density and resisting vibration common in industrial environments.\u003c\/p\u003e","brand":"YOKOGAWA","offers":[{"title":"Default Title","offer_id":51775516836152,"sku":"ARM55C","price":188.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/ARM55C1.jpg?v=1770774574","url":"https:\/\/www.automodulexpert.com\/products\/arm55c-relay-board-yokogawa","provider":"AutoModuleXpert Ltd.","version":"1.0","type":"link"}