{"product_id":"asi133-h00-sa3s0-yokogawa-analog-input-module","title":"ASI133-H00\/SA3S0  Yokogawa Analog Input Module","description":"\u003ch3\u003eFunctional Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eASI133-H00\/SA3S0\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-performance analog input module engineered for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYokogawa FIO (Field Interface Option)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esystem architecture. It enables precise conversion of analog field signals into digital data for process control systems, supporting\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eup to eight independent input channels\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThe module incorporates\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003erobust electrical isolation between channels and system circuitry\u003c\/strong\u003e, effectively minimizing\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ecommon-mode noise\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand preventing\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eground loop interference\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ein demanding industrial environments. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eASI133-H00\/SA3S0\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis commonly used to acquire process variables such as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003epressure, temperature, and flow\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ethrough standard\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e4–20 mA current loops\u003c\/strong\u003e, ensuring reliable data transmission to\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDCS and SCADA platforms\u003c\/strong\u003e.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Density\u003c\/td\u003e\n\u003ctd\u003e8 channels (non-isolated or channel-to-channel isolated depending on backplane configuration)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Signal Range\u003c\/td\u003e\n\u003ctd\u003e4–20 mA DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Impedance\u003c\/td\u003e\n\u003ctd\u003e250 Ω (typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Input Current\u003c\/td\u003e\n\u003ctd\u003e30 mA DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConversion Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.1% of full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Refresh Cycle\u003c\/td\u003e\n\u003ctd\u003e≤ 10 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDielectric Strength\u003c\/td\u003e\n\u003ctd\u003e1500 V AC between input terminals and system ground\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e150 mA @ 5 V DC (internal system bus)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnection Interface\u003c\/td\u003e\n\u003ctd\u003eSA3S0 dedicated terminal block\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e152 mm × 127 mm × 38 mm (H × W × D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eOperational Scenarios\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eASI133-H00\/SA3S0\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis widely deployed in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eupstream oil and gas facilities, water treatment plants, and pharmaceutical production lines\u003c\/strong\u003e. It serves as a critical interface for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e2-wire and 4-wire transmitters\u003c\/strong\u003e, enabling high-precision acquisition of analog process signals.\u003c\/p\u003e\n\u003cp\u003eWhen integrated into a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYokogawa FIO node\u003c\/strong\u003e, the module provides\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ehigh-speed data acquisition with minimal latency\u003c\/strong\u003e, which is essential for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePID control loops, continuous process optimization, and safety monitoring systems\u003c\/strong\u003e.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the difference between the H00 and other suffixes?\u003c\/strong\u003e\u003cbr\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eH00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edesignation indicates the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003estandard hardware revision without additional environmental coating\u003c\/strong\u003e, while\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSA3S0\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003especifies the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eincluded terminal block assembly\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprovided with the module.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this module support HART passthrough?\u003c\/strong\u003e\u003cbr\u003eNo. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eASI133-H00\/SA3S0\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003estandard analog input module\u003c\/strong\u003e. For\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHART communication support\u003c\/strong\u003e, users should consider modules in the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAAI143 series\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eor verify compatibility with specific\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFIO carrier configurations\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs the terminal block hot-swappable?\u003c\/strong\u003e\u003cbr\u003eYes. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFIO architecture\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esupports\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ehot replacement of the module while the system remains powered\u003c\/strong\u003e, provided that proper\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003esafety procedures for the installation environment (especially hazardous areas)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eare followed.\u003c\/p\u003e","brand":"YOKOGAWA","offers":[{"title":"Default Title","offer_id":51864997495096,"sku":"ASI133-H00\/SA3S0","price":188.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/ASI133-H00SA3S0.jpg?v=1773021413","url":"https:\/\/www.automodulexpert.com\/products\/asi133-h00-sa3s0-yokogawa-analog-input-module","provider":"AutoModuleXpert Ltd.","version":"1.0","type":"link"}