{"product_id":"bachmann-aio288-m1-8-ch-analog-input-output-module","title":"Bachmann AIO288 M1 8-Ch Analog Input\/Output Module","description":"\u003ch2\u003eBachmann AIO288 M1 Analog Input\/Output Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eBachmann AIO288\u003c\/strong\u003e is a combination analog input\/output module for the Bachmann M1 automation system, integrating 8 analog input channels and 8 analog output channels on a single unit. It processes +\/-1 V and +\/-10 V voltage signals, 0-20 mA current loops, up to 4 Pt100\/Pt1000 RTD sensors, and up to 4 potentiometer channels with 14-bit resolution, a 200 us sampling time, and 500 V galvanic isolation from the system.\u003c\/p\u003e\n\u003ch3\u003eAnalog Input and Sensor Measurement\u003c\/h3\u003e\n\u003cp\u003eThe 8 analog input channels accept +\/-1 V and +\/-10 V voltage signals (input impedance greater than 100 kOhm, +\/-0.05% accuracy) as well as 0-20 mA current inputs (243 Ohm input impedance, 35 mA maximum input current, +\/-0.1% accuracy). Inputs support configurable single-ended or differential wiring with a 1.5 kHz input cutoff frequency and 200 us sampling time.\u003c\/p\u003e\n\u003cp\u003eUp to 4 channels can be used for Pt100 or Pt1000 temperature sensors across -100 deg C to +500 deg C using 2-wire or 4-wire RTD connections, or for potentiometer measurement with a +\/-10 V excitation supply rated up to 40 mA maximum load. Diagnostic monitoring includes wire-break detection on sensor circuits.\u003c\/p\u003e\n\u003ch3\u003eAnalog Output and Isolation\u003c\/h3\u003e\n\u003cp\u003eThe 8 analog output channels deliver +\/-10 V signals with +\/-0.025% measuring-range accuracy and 14-bit digital resolution. Output circuits incorporate short-circuit protection and overload monitoring to protect field wiring and internal drivers.\u003c\/p\u003e\n\u003cp\u003eA 500 V galvanic isolation barrier separates the field analog circuitry from the M1 system backplane, reducing ground-loop interference across mixed signal types.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eAIO288\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBachmann\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eBachmann Electronic GmbH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Series\u003c\/td\u003e\n\u003ctd\u003eM1 Automation System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eAnalog Input\/Output Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Input Channels\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Output Channels\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Input Range\u003c\/td\u003e\n\u003ctd\u003e+\/-1 V \/ +\/-10 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Input Range\u003c\/td\u003e\n\u003ctd\u003e0-20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Output Range\u003c\/td\u003e\n\u003ctd\u003e+\/-10 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Resolution\u003c\/td\u003e\n\u003ctd\u003e14 bit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Input Impedance\u003c\/td\u003e\n\u003ctd\u003eGreater than 100 kOhm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Input Impedance\u003c\/td\u003e\n\u003ctd\u003e243 Ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Current Input\u003c\/td\u003e\n\u003ctd\u003e35 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Sensor Types\u003c\/td\u003e\n\u003ctd\u003ePt100 \/ Pt1000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Input Channels\u003c\/td\u003e\n\u003ctd\u003eUp to 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Range\u003c\/td\u003e\n\u003ctd\u003e-100 deg C to +500 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRTD Connection\u003c\/td\u003e\n\u003ctd\u003e2-wire \/ 4-wire\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePotentiometer Supply\u003c\/td\u003e\n\u003ctd\u003eUp to 4 channels, +\/-10 V, 40 mA maximum load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSampling Time\u003c\/td\u003e\n\u003ctd\u003e200 us\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Cutoff Frequency\u003c\/td\u003e\n\u003ctd\u003e1.5 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Output Accuracy\u003c\/td\u003e\n\u003ctd\u003e+\/-0.025% of measuring range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Input Accuracy\u003c\/td\u003e\n\u003ctd\u003e+\/-0.05% of input voltage range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Input Accuracy\u003c\/td\u003e\n\u003ctd\u003e+\/-0.1% of measuring range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGalvanic Isolation\u003c\/td\u003e\n\u003ctd\u003e500 V from system\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e120 x 75 x 30 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.25 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How many RTD temperature sensors can connect to the Bachmann AIO288? A: The module supports up to 4 Pt100 or Pt1000 temperature sensors using 2-wire or 4-wire connections across a -100 deg C to +500 deg C range.\u003c\/p\u003e\n\u003cp\u003eQ: What signal ranges and resolution does the AIO288 support? A: It provides 14-bit resolution with +\/-1 V, +\/-10 V, and 0-20 mA inputs (plus potentiometer excitation up to 4 channels at +\/-10 V, 40 mA max) and +\/-10 V analog outputs.\u003c\/p\u003e\n\u003cp\u003eQ: What electrical protection and diagnostics are built into the AIO288? A: The module includes 500 V galvanic isolation from the system, wire-break detection, short-circuit-protected outputs, and overload monitoring.\u003c\/p\u003e","brand":"BACHMANN","offers":[{"title":"Default Title","offer_id":51476194525496,"sku":"AIO288","price":185.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/582_b88c2f5c-6feb-412e-b675-436aef66d3b1.jpg?v=1795159353","url":"https:\/\/www.automodulexpert.com\/products\/bachmann-aio288-m1-8-ch-analog-input-output-module","provider":"AutoModuleXpert Ltd.","version":"1.0","type":"link"}