{"product_id":"c200dbi001-ea-ge-fanuc-network-interface-module","title":"C200DBI001-EA GE Fanuc Network Interface Module","description":"\u003cp\u003eConfigured for high-speed data orchestration in Versamax control networks, the \u003cstrong\u003eGE Fanuc IC200DBI001-EA\u003c\/strong\u003e (\u003cstrong\u003eIC200DBI001-EA\u003c\/strong\u003e Remote I\/O Network Interface Module) provides direct physical\/electrical execution. This module manages local I\/O bus traffic, converting field-level communication data into structured packets for transmission across the primary backplane control network.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC200DBI001-EA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eVerify via product label\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.69 lbs (0.31 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard Versamax module footprint\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eBackplane dependent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eI\/O Type\u003c\/td\u003e\n\u003ctd\u003eRemote I\/O Network Interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatibility\u003c\/td\u003e\n\u003ctd\u003eVersamax Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProfinet \/ EtherNet\/IP Deterministic Networks\u003c\/h3\u003e\n\u003cp\u003eThe IC200DBI001-EA module facilitates deterministic communication by maintaining consistent polling intervals between the field devices and the master controller. It performs real-time data translation to ensure the integrity of cyclic data packets within the Versamax platform. The interface logic handles frame buffering and error detection to minimize communication latencies. Firmware flash compatibility is maintained through the primary configuration port, allowing for controlled updates to the interface protocol stack without requiring complete hardware replacement.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can this module be configured for redundant network topologies?\u003c\/p\u003e\n\u003cp\u003eA: The IC200DBI001-EA operates within the standard Versamax architecture. Implementation of redundant network paths depends on the host CPU capability and the underlying network protocol configuration.\u003c\/p\u003e\n\u003cp\u003eQ: What is the impact of firmware version mismatches on module communication?\u003c\/p\u003e\n\u003cp\u003eA: Firmware mismatches may lead to communication timeouts or inconsistent I\/O data mapping. Always ensure the module firmware version is compatible with the configuration software project settings.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDIN-Rail Mounting: Secure the module onto a grounded 35 mm DIN rail. Ensure the locking latch is fully engaged to maintain electrical continuity between the module chassis and the rail.\u003c\/li\u003e\n\u003cli\u003eCommunication Cabling: Utilize shielded Ethernet cabling for all network interface ports. Terminate shields at the recommended grounding point to minimize electromagnetic interference (EMI) ingress.\u003c\/li\u003e\n\u003cli\u003ePower Distribution: Verify that the 24 VDC auxiliary power supply (if applicable) is within specified limits before connecting to the module to avoid damage to the communication transceivers.\u003c\/li\u003e\n\u003cli\u003eModule Addressing: Confirm that all DIP switches or software-defined node addresses are correctly configured before powering on the segment to prevent network address conflicts.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE FANUC","offers":[{"title":"Default Title","offer_id":52435777978680,"sku":"IC200DBI001-EA","price":220.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/IC200DBI001-EA1.jpg?v=1780040073","url":"https:\/\/www.automodulexpert.com\/products\/c200dbi001-ea-ge-fanuc-network-interface-module","provider":"AutoModuleXpert Ltd.","version":"1.0","type":"link"}