{"product_id":"ci867ak01-3bse092689r1ac-abb-800m-modbus-tcp-interface","title":"CI867AK01 3BSE092689R1AC ABB 800M Modbus TCP Interface","description":"\u003ch2\u003eABB CI867AK01 3BSE092689R1 AC 800M Communication Interface Package\u003c\/h2\u003e\n\u003cp\u003eConfigured for Modbus TCP Ethernet protocol execution in System 800xA network architectures, the \u003cstrong\u003eABB CI867AK01\u003c\/strong\u003e (\u003cstrong\u003eCI867A\u003c\/strong\u003e Modbus TCP Communication Interface Package) provides direct physical\/electrical execution. The assembly mounts on a CEX-Bus backplane via the TP867 baseplate to manage master and slave data messaging between an AC 800M controller and external Ethernet field networks.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCI867AK01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eArticle Number\u003c\/td\u003e\n\u003ctd\u003e3BSE092689R1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBase Module\u003c\/td\u003e\n\u003ctd\u003eCI867A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Baseplate\u003c\/td\u003e\n\u003ctd\u003eTP867\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eSweden\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e700 g (including baseplate)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e59 x 185 x 127.5 mm (W x H x D, including baseplate)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to +55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eSupplied via +24 VDC CEX-Bus (Onboard DC\/DC converter)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eCommunication Interface Modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtocol\u003c\/td\u003e\n\u003ctd\u003eModbus TCP (Level 7 OSI application layer)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthernet Port\u003c\/td\u003e\n\u003ctd\u003e1 x RJ-45 female (8-pin)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransmission Speed\u003c\/td\u003e\n\u003ctd\u003e10\/100 Mbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLine Redundancy\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Redundancy\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHot Swap\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Units on CEX Bus\u003c\/td\u003e\n\u003ctd\u003e12 per AC 800M controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Devices\u003c\/td\u003e\n\u003ctd\u003e70 Slave units, 8 Master units per CI867A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5-95%, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Altitude\u003c\/td\u003e\n\u003ctd\u003e2000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePollution Degree\u003c\/td\u003e\n\u003ctd\u003eDegree 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHarsh Environment\u003c\/td\u003e\n\u003ctd\u003eG3 coating according to ISA 71.04\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Class\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eSystem 800xA 6.0.3.3, 6.1.1, and subsequent versions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eCEX-Bus Communication Logic and Network Execution\u003c\/h3\u003e\n\u003cp\u003eThe CI867A expansion unit houses CEX-Bus protocol logic, an integrated Ethernet communication processor, and an internal DC\/DC converter. The converter draws primary power from the controller's +24 VDC CEX-Bus power rail to generate internal operating voltages. Operating over a single 10\/100 Mbit\/s RJ-45 Ethernet port, the interface module establishes Modbus TCP request-response framing across standard TCP\/IP network infrastructures via an external Ethernet switch. The module supports hot-swappable installation, allowing online replacement without de-energizing adjacent modules on the backplane rail. Module redundancy ensures uninterrupted execution of client and server socket connections during primary module failover.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can the CI867A module perform hot swap operations during system runtime?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the CI867A communication interface supports hot swapping on the TP867 baseplate. Removing the module does not disrupt the main CEX-Bus power rail or communication continuity to other backplane expansion units.\u003c\/p\u003e\n\u003cp\u003eQ: How many Modbus TCP slave and master devices can a single CI867A interface manage?\u003c\/p\u003e\n\u003cp\u003eA: A single CI867A interface handles connections to a maximum of 70 Modbus TCP slave units and up to 8 Modbus TCP master units simultaneously.\u003c\/p\u003e\n\u003cp\u003eQ: What software version is required to run the CI867A interface?\u003c\/p\u003e\n\u003cp\u003eA: The CI867A hardware module requires ABB System 800xA version 6.0.3.3, 6.1.1, or subsequent software versions along with matching Compact Control Builder software.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBaseplate Mounting:\u003c\/strong\u003e Secure the TP867 baseplate directly to the DIN rail and engage the CEX-Bus side connector before locking the mechanical latches. Align the physical keying mechanism to verify baseplate engagement.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule Insertion:\u003c\/strong\u003e Align the CI867A module guide pins with the TP867 baseplate connector. Press firmly until the latch mechanisms lock completely onto the baseplate rail.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNetwork Cabling:\u003c\/strong\u003e Connect a shielded CAT5e or CAT6 Ethernet cable with an 8-pin RJ-45 connector to the Ethernet port. Ensure the cable shield terminates to the cabinet functional earth rail through low-impedance grounding clamps.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBus Termination and Power Verification:\u003c\/strong\u003e Verify that the CEX-Bus layout does not exceed 12 total communication units per controller. Ensure system supply voltage stays within standard +24 VDC limits before energizing the cabinet.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":53049090375992,"sku":"CI867AK01 3BSE092689R1","price":188.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/636._b13f8d7f-9385-414a-a2b5-f6ca644d2f16.jpg?v=1790579040","url":"https:\/\/www.automodulexpert.com\/products\/ci867ak01-3bse092689r1ac-abb-800m-modbus-tcp-interface","provider":"AutoModuleXpert Ltd.","version":"1.0","type":"link"}