{"product_id":"communication-interface-module-abb-inict13a-inict13a","title":"Communication Interface Module | ABB INICT13A INICT13A","description":"\u003ch2\u003eABB INICT13A Symphony Plus Transfer Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eABB INICT13A\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eINICT13A\u003c\/strong\u003e Communication Interface Module, operates as a dedicated hardware component for network data transfer and I\/O bus interface management within ABB Symphony Plus platforms. Operating on 24 VDC supplied directly from the rack backplane, the unit coordinates dual redundant ModuleBus interfaces across 800xA and Symphony Plus node configurations. The module routes proprietary protocol packets between local field I\/O racks and control execution networks while providing 5 VDC, 2 A bus power distribution and galvanic signal isolation.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eINICT13A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eSweden\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.25 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e120 mm x 80 mm x 40 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to +55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e3 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC (via backplane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Current\u003c\/td\u003e\n\u003ctd\u003e5 VDC, 2 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Ports\u003c\/td\u003e\n\u003ctd\u003eDual redundant ModuleBus interfaces\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Rating\u003c\/td\u003e\n\u003ctd\u003eIP20 (IEC 60529)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Communication Velocity and Deterministic Networks\u003c\/h3\u003e\n\u003cp\u003eThe INICT13A module maintains high backplane bus communication velocity across S800 I\/O backplane racks by executing deterministic protocol conversions without introducing pipeline delay. Galvanic channel isolation filters high-frequency noise spikes away from sensitive backplane logic rails, protecting the internal CPU against common-mode voltage fluctuations. Front-panel status LEDs provide real-time hardware diagnostics for bus activity and active channel switching, ensuring complete firmware flash compatibility during online node reconfiguration or live card extraction.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How does the INICT13A handle communication loss on its primary ModuleBus channel?\u003c\/p\u003e\n\u003cp\u003eA: The hardware architecture incorporates dual redundant ModuleBus ports that trigger an instantaneous, deterministic switchover to the secondary bus path without interrupting process control loops.\u003c\/p\u003e\n\u003cp\u003eQ: Can maintenance personnel hot-swap the INICT13A module during active system operation?\u003c\/p\u003e\n\u003cp\u003eA: Hot-swapping must follow strict rack isolation protocols; verify that redundant communication paths are active before extracting the module to prevent field bus address disruption on adjacent nodes.\u003c\/p\u003e\n\u003cp\u003eQ: What power outputs does the INICT13A supply to connected backplane components?\u003c\/p\u003e\n\u003cp\u003eA: The module converts 24 VDC backplane input power down to regulated 5 VDC at up to 2 A to drive internal bus logic circuits for connected S800 I\/O cards.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eMount the INICT13A module securely onto the standard DIN rail slot within the S800 I\/O enclosure, ensuring full engagement of the rear backplane connectors. Route all ModuleBus communication cables through dedicated wire raceways separated from high-voltage AC power lines to minimize electromagnetic noise. Verify that the enclosure provides IP54 or NEMA 12 environmental sealing to maintain ambient operating temperatures between 0 and +55 deg C. Ensure the mounting rail connects directly to the central cabinet protective earth bar to maintain effective shielding ground.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":52939053302072,"sku":"INICT13","price":188.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/557.jpg?v=1789110014","url":"https:\/\/www.automodulexpert.com\/products\/communication-interface-module-abb-inict13a-inict13a","provider":"AutoModuleXpert Ltd.","version":"1.0","type":"link"}