{"product_id":"communication-processor-module-yokogawa-cp461-e1","title":"Communication Processor Module Yokogawa CP461-E1","description":"\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCP461-E1 (P\/N: CP461-E1)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-speed communication gateway designed for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYokogawa CENTUM VP Distributed Control System (DCS)\u003c\/strong\u003e. It functions as a critical interface between the CENTUM VP control network and external subsystems or third-party equipment. Built on a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003edual-core ARM Cortex-A9\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003earchitecture, the module reliably manages high data volumes without impacting deterministic process control performance.\u003c\/p\u003e\n\u003cp\u003eWith integrated\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGigabit Ethernet\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand flexible\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eserial communication interfaces (RS-232\/RS-485)\u003c\/strong\u003e, the CP461-E1 enables real-time data exchange with PLCs, power management systems, and intelligent field devices. Its\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e2GB DDR3 memory\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esupports stable protocol handling and buffering, while\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eindustrial-grade NAND flash storage\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eensures secure retention of configuration and system data.\u003c\/p\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eComputing Core\u003c\/td\u003e\n\u003ctd\u003eDual-core ARM Cortex-A9 Processor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Memory\u003c\/td\u003e\n\u003ctd\u003e2GB DDR3 SDRAM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage\u003c\/td\u003e\n\u003ctd\u003e4GB NAND Flash\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthernet Interfaces\u003c\/td\u003e\n\u003ctd\u003e2 × 10\/100\/1000Base-T (RJ45)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSerial Interfaces\u003c\/td\u003e\n\u003ctd\u003e2 × RS-232, 2 × RS-485\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Throughput\u003c\/td\u003e\n\u003ctd\u003eUp to 1 Gbps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcessing Latency\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 1 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePacket Loss Rate\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 0.01%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0°C to 55°C (32°F to 131°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eSystem Functionality\u003c\/h2\u003e\n\u003cp\u003eThe CP461-E1 enables seamless integration of\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eheterogeneous automation systems\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ewithin the CENTUM VP environment. It allows monitoring and control of non-Yokogawa equipment using standardized industrial communication protocols. By offloading communication tasks from the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eField Control Station (FCS)\u003c\/strong\u003e, it preserves CPU resources for critical control logic execution and enhances overall system responsiveness.\u003c\/p\u003e\n\u003ch2\u003eFAQ\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the CP461-E1 support redundant network configurations?\u003c\/strong\u003e\u003cbr\u003eA: Yes. The dual Ethernet ports support physical network redundancy, ensuring continued communication if one cable or switch port fails.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is the CP461-E1 compatible with older CENTUM systems?\u003c\/strong\u003e\u003cbr\u003eA: The CP461-E1 is optimized for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCENTUM VP\u003c\/strong\u003e. Compatibility with legacy CENTUM systems depends on the specific FCS and bus converter hardware versions in use.\u003c\/p\u003e","brand":"YOKOGAWA","offers":[{"title":"Default Title","offer_id":51636540145976,"sku":"CP461-E1","price":188.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/CP461-E12.jpg?v=1768982013","url":"https:\/\/www.automodulexpert.com\/products\/communication-processor-module-yokogawa-cp461-e1","provider":"AutoModuleXpert Ltd.","version":"1.0","type":"link"}