{"product_id":"con021-pr6423-000-120-emerson-eddy-current-sensor-system","title":"CON021+PR6423\/000-120 Emerson Eddy Current Sensor System","description":"\u003ch2\u003eEmerson CON021+PR6423\/000-120 Eddy Current Proximity Measurement System\u003c\/h2\u003e\n\u003cp\u003eThe Emerson \u003cstrong\u003eCON021+PR6423\/000-120\u003c\/strong\u003e is a non-contact eddy current displacement measurement assembly combining a PR6423\/000-120 proximity probe with a CON021 signal converter. It measures shaft vibration, radial and axial displacement, shaft position, eccentricity, and speed on rotating machinery without physical contact. Specifications list an 8 mm probe tip diameter, a 2 mm measurement range, 8 V\/mm (+- 5%) sensitivity, and a 0–20 kHz (-3 dB) converter frequency response.\u003c\/p\u003e\n\u003ch3\u003eSensing and Signal Conditioning\u003c\/h3\u003e\n\u003cp\u003eNon-contact eddy current sensing detects changes in gap distance between the sensing tip and a conductive metal target to track shaft vibration, axial displacement, and shaft position without mechanical wear. In this configuration, the CON021 converter powers probe excitation and outputs a conditioned electrical signal for machinery monitoring and protection systems.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eTarget and Gap Geometry:\u003c\/strong\u003e Tuned for ferromagnetic steel targets such as 42CrMo4 \/ AISI 4140 with a minimum shaft diameter of 25 mm and a 0.5 mm initial air gap.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement and Linearity:\u003c\/strong\u003e Provides a 2 mm measurement range, 8 V\/mm (+- 5%) sensitivity, and +- 0.025 mm linearity deviation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDynamic Response:\u003c\/strong\u003e Converter frequency response covers 0–20 kHz (-3 dB) with a rise time of less than 15 us.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePower, Output, and Environmental Ratings\u003c\/h3\u003e\n\u003cp\u003eThe probe is rated for -35 deg C to +180 deg C (specified for the sensor with a 1 m cable) and includes an IP66 protection rating in the probe overview. Converter supply voltage is -23 to -32 VDC or -21 to -32 VDC depending on output range, with output ranges of -4 to -20 V or -2 to -18 V and -30 deg C to +100 deg C operating temperature.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupply and Output Coupling:\u003c\/strong\u003e Converter supply (-23 to -32 VDC or -21 to -32 VDC) and output (-4 to -20 V or -2 to -18 V) depend on the selected output range configuration; overview notes also mention 4-20 mA or 0-10 V DC outputs and IP65 converter protection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermal and Ingress Limits:\u003c\/strong\u003e Probe operates from -35 deg C to +180 deg C (with 1 m cable noted in the specification table), while the converter operates from -30 deg C to +100 deg C with IP20 protection listed in the system table.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCON021+PR6423\/000-120\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eEmerson (EPRO)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eEddy Current Sensor and Signal Converter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe Model\u003c\/td\u003e\n\u003ctd\u003ePR6423\/000-120\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConverter Model\u003c\/td\u003e\n\u003ctd\u003eCON021\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor Type\u003c\/td\u003e\n\u003ctd\u003e8 mm non-contact eddy-current probe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Range\u003c\/td\u003e\n\u003ctd\u003e2 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInitial Air Gap\u003c\/td\u003e\n\u003ctd\u003e0.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensitivity\u003c\/td\u003e\n\u003ctd\u003e8 V\/mm (+- 5%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLinearity Deviation\u003c\/td\u003e\n\u003ctd\u003e+- 0.025 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Shaft Diameter\u003c\/td\u003e\n\u003ctd\u003e25 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTarget Material\u003c\/td\u003e\n\u003ctd\u003eFerromagnetic steel, standard 42CrMo4 \/ AISI 4140\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe Protection\u003c\/td\u003e\n\u003ctd\u003eIP66\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe Temperature\u003c\/td\u003e\n\u003ctd\u003e-35 deg C to +180 deg C (sensor with 1 m cable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConverter Frequency Response\u003c\/td\u003e\n\u003ctd\u003e0–20 kHz (-3 dB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConverter Rise Time\u003c\/td\u003e\n\u003ctd\u003eLess than 15 us\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConverter Supply Voltage\u003c\/td\u003e\n\u003ctd\u003e-23 to -32 VDC or -21 to -32 VDC, depending on output range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConverter Output Range\u003c\/td\u003e\n\u003ctd\u003e-4 to -20 V or -2 to -18 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConverter Protection\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConverter Operating Temperature\u003c\/td\u003e\n\u003ctd\u003e-30 deg C to +100 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003cp\u003eFrequently Asked Questions\u003c\/p\u003e\n\u003cp\u003eQ: What measuring range, initial air gap, and linearity apply to the CON021+PR6423\/000-120? A: Specifications list a 2 mm measurement range, a 0.5 mm initial air gap, 8 V\/mm (+- 5%) sensitivity, +- 0.025 mm linearity deviation, and a 25 mm minimum shaft diameter. Verify shaft material calibration and monitoring input scaling before commissioning.\u003c\/p\u003e\n\u003cp\u003eQ: How do the converter supply voltage and output range relate? A: The converter supply is -23 to -32 VDC or -21 to -32 VDC depending on output range, paired with -4 to -20 V or -2 to -18 V output ranges. Confirm the exact CON021 configuration and power margin against your monitoring channel requirements.\u003c\/p\u003e\n\u003cp\u003eQ: Why do the source notes show differences in converter output and IP rating details? A: The system specification table lists -4 to -20 V or -2 to -18 V outputs and IP20 converter protection (with -30 deg C to +100 deg C operating temperature), whereas CON021 overview notes mention 4-20 mA or 0-10 V DC outputs and IP65 protection. Confirm the exact converter hardware revision and enclosure rating before ordering.\u003c\/p\u003e","brand":"EPRO","offers":[{"title":"Default Title","offer_id":51483809939768,"sku":"CON021+PR6423\/000-120","price":256.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/CON021_PR6424000-1002.jpg?v=1765157823","url":"https:\/\/www.automodulexpert.com\/products\/con021-pr6423-000-120-emerson-eddy-current-sensor-system","provider":"AutoModuleXpert Ltd.","version":"1.0","type":"link"}