{"product_id":"controller-iota-termination-module-honeywell-cc-tcnt01-c300","title":"Controller IOTA Termination Module | Honeywell CC-TCNT01 C300","description":"\u003ch2\u003eHoneywell CC-TCNT01 C300 Controller IOTA\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell CC-TCNT01\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eCC-TCNT01\u003c\/strong\u003e C300 Controller Input\/Output Termination Assembly, operates as a dedicated hardware component for power distribution and signal routing within Honeywell Experion PKS Series C platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCC-TCNT01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eStandard Series C module rating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard Series C IOTA footprint\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 deg C to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e0.311 A @ 24 VDC (0 A base IOTA draw)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e51308307-175\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eC300 Controller Input\/Output Terminal Assembly (IOTA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Series\u003c\/td\u003e\n\u003ctd\u003eExperion PKS Series C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Power Reference\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible Controller\u003c\/td\u003e\n\u003ctd\u003eCC-PCNT01 C300 Controller Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Type\u003c\/td\u003e\n\u003ctd\u003eSeries C cabinet carrier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eChannel Isolation and Process Interface Operations\u003c\/h3\u003e\n\u003cp\u003eThe terminal assembly routes primary system power and execution communications across the distributed control architecture. By providing direct physical landing points for Fault-Tolerant Ethernet (FTE), IO Link, redundancy connections, battery backup feeds, and time source synchronization cables, the assembly establishes signal continuity across the controller sub-plane. Channel-to-channel isolation protocols prevent field-side transient voltages from interfering with backplane logic execution, while integrated power distribution buses supply regulated 24 VDC current directly to the mounted processor hardware.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the CC-TCNT01 assembly execute control logic independently without an attached processor? A: No. The CC-TCNT01 functions strictly as a physical termination and mounting assembly; logic execution requires the separate installation of a compatible CC-PCNT01 C300 controller module.\u003c\/p\u003e\n\u003cp\u003eQ: How is field cabling grounded on the CC-TCNT01 termination assembly? A: Field cable shields connect directly to the integrated shield bar on the Series C cabinet carrier, maintaining low-impedance earth grounding to suppress industrial high-frequency noise.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eLock the CC-TCNT01 securely onto the designated slots of the Series C cabinet carrier.\u003c\/li\u003e\n\u003cli\u003eConnect the primary 24 VDC cabinet power harness to the IOTA power input terminals, verifying correct polarity prior to energizing.\u003c\/li\u003e\n\u003cli\u003eRoute network cables including FTE, IO Link, and redundancy interconnects through dedicated wire channels to avoid cross-talk with high-voltage power lines.\u003c\/li\u003e\n\u003cli\u003eAlign the CC-PCNT01 controller module with the IOTA connector pin array and push firmly until the mechanical locking latches engage fully.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"HONEYWELL","offers":[{"title":"Default Title","offer_id":49278334927160,"sku":"CC-TCNT01","price":235.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/657._ff6ab2ad-5acb-44f5-a56d-bf35e7e3ae9f.jpg?v=1792389455","url":"https:\/\/www.automodulexpert.com\/products\/controller-iota-termination-module-honeywell-cc-tcnt01-c300","provider":"AutoModuleXpert Ltd.","version":"1.0","type":"link"}