{"product_id":"csl-adm12c-22c-yokogawa-contact-input-module","title":"CSL\/ADM12C\/22C  Yokogawa Contact Input Module","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCSL\/ADM12C\/22C\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efrom\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYokogawa\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-density digital input module designed for large-scale Distributed Control Systems (DCS). This contact input module monitors\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e32 independent digital points\u003c\/strong\u003e, making it ideal for complex automation environments that require precise status tracking of field devices such as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003elimit switches, pushbuttons, and relay contacts\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eUnlike traditional screw-terminal modules, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCSL\/ADM12C\/22C\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003euses a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003econnector-type interface\u003c\/strong\u003e, significantly reducing installation time while maintaining high signal integrity through standardized cabling. The module is designed to operate within a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYokogawa I\/O module nest\u003c\/strong\u003e, providing a compact and reliable interface between field hardware and the central controller.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Number\u003c\/td\u003e\n\u003ctd\u003eCSL\/ADM12C\/22C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDevice Category\u003c\/td\u003e\n\u003ctd\u003eContact Input Module (Digital Input)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Density\u003c\/td\u003e\n\u003ctd\u003e32 Points per module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterface Type\u003c\/td\u003e\n\u003ctd\u003eConnector Type (Requires KS9 \/ KS10 cabling)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical Contact Rating\u003c\/td\u003e\n\u003ctd\u003e5 V DC, 20 mA minimum (external contact standard)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTiming Requirements\u003c\/td\u003e\n\u003ctd\u003eMinimum pulse width 40 ms; pulse frequency up to 10 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e600 mA maximum at 5.0 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThermal Dissipation\u003c\/td\u003e\n\u003ctd\u003eHeat dissipation factor of 0.6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Configuration\u003c\/td\u003e\n\u003ctd\u003eCommon minus isolation per 16 input points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Method\u003c\/td\u003e\n\u003ctd\u003eDirect installation into I\/O module nest\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupported Terminal Board\u003c\/td\u003e\n\u003ctd\u003eTE32 Terminal Board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e 1.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eAdvanced Signal Processing\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCSL\/ADM12C\/22C\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis optimized for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003edry contact signal monitoring\u003c\/strong\u003e, using\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5 V DC interrogation signals\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto reliably detect contact status even in electrically noisy industrial environments.\u003c\/p\u003e\n\u003cp\u003eThe module architecture divides the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e32 input channels into two isolated groups of 16\u003c\/strong\u003e, each with a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ecommon negative return path\u003c\/strong\u003e. This design simplifies field wiring while protecting the internal logic of the DCS from\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eground potential differences and electrical disturbances\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eCompatibility with\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eKS9 and KS10 interface cables\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eenables flexible cabinet layouts and straightforward connections to the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eTE32 terminal board\u003c\/strong\u003e, improving installation efficiency and simplifying maintenance or troubleshooting tasks.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat differentiates the CSL\/ADM12C\/22C from standard input modules?\u003c\/strong\u003e\u003cbr\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCSL designation\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e22C suffix\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003etypically represent a specific configuration within the Yokogawa hardware ecosystem, often optimized for particular generations of\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCENTUM distributed control systems\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs the cabling included with the module?\u003c\/strong\u003e\u003cbr\u003eNo. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eKS9 or KS10 connector cables\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003erequired to link the module to the terminal board must be\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003epurchased separately\u003c\/strong\u003e, depending on the installation distance and cabinet layout.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the common minus side isolation work?\u003c\/strong\u003e\u003cbr\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e32 digital inputs are divided into two groups of 16 channels\u003c\/strong\u003e. Each group shares a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ecommon negative return\u003c\/strong\u003e, simplifying wiring while maintaining electrical separation between the groups to enhance system protection and signal stability.\u003c\/p\u003e","brand":"YOKOGAWA","offers":[{"title":"Default Title","offer_id":51881967878456,"sku":"CSL\/ADM12C\/22C","price":188.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/CSLADM12C22C2.jpg?v=1773280138","url":"https:\/\/www.automodulexpert.com\/products\/csl-adm12c-22c-yokogawa-contact-input-module","provider":"AutoModuleXpert Ltd.","version":"1.0","type":"link"}