{"product_id":"dc-dc-system-power-supply-module-emerson-deltav-ve5008","title":"DC\/DC System Power Supply Module | Emerson DeltaV VE5008","description":"\u003ch2\u003eEmerson VE5008 DeltaV System Power Supply\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eEmerson VE5008\u003c\/strong\u003e is a DC\/DC system power supply module for Emerson DeltaV Distributed Control Systems. It accepts 12 VDC or 24 VDC input power and generates regulated system rails including 12 VDC, 5 VDC, and 3.3 VDC for controllers and I\/O subsystems. Source materials show conflicting details on series assignment (DeltaV M-Series vs. S-Series) and output ratings, so verify exact hardware revision and carrier compatibility before ordering.\u003c\/p\u003e\n\u003ch3\u003ePower Conversion and Output Rails\u003c\/h3\u003e\n\u003cp\u003eIn the DeltaV M-Series specification, the module takes a 12 VDC (-4% to +5% tolerance) or 24 VDC (+\/-20% tolerance) input and produces a 12 VDC main rail along with 5 VDC and 3.3 VDC auxiliary outputs. Input current is rated at 14.8 A at 12 VDC and 6.1 A at 24 VDC, with 12 VDC output capacity specified at 13 A from a 12 VDC source or 8 A from a 24 VDC source.\u003c\/p\u003e\n\u003cp\u003eEach auxiliary rail provides up to 2 A, subject to a 10 W maximum combined auxiliary output power limit. Overvoltage protection is rated at 110-120% of nominal output, and input protection uses an internal fuse.\u003c\/p\u003e\n\u003ch3\u003eConflicting Source Details and Operating Limits\u003c\/h3\u003e\n\u003cp\u003eThe two source texts disagree on key specifications: one describes a DeltaV M-Series DC\/DC supply with 12 VDC \/ 5 VDC \/ 3.3 VDC outputs, passive convection cooling, and derating above +60 deg C, while the other describes a DeltaV S-Series dual\/redundant 24 VDC power supply (5 A per supply, 10 A total, hot-swappable, 0.9 kg, ATEX and IECEx). Because these specs conflict, treat unverified cross-source claims with caution and check the physical label and carrier before installation.\u003c\/p\u003e\n\u003cp\u003eWhere documented, operating and storage temperatures span -40 deg C to +70 deg C with 5-95% non-condensing relative humidity. Mounting is specified for a DeltaV M-Series carrier with passive convection cooling.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eVE5008\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eEmerson\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eDC\/DC System Power Supply (conflicting: Dual Power Supply Module)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eDeltaV M-Series (conflicting: DeltaV S-Series)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e12 VDC or 24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e12 VDC Input Tolerance\u003c\/td\u003e\n\u003ctd\u003e-4% to +5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e24 VDC Input Tolerance\u003c\/td\u003e\n\u003ctd\u003e+\/-20%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Current (12 VDC)\u003c\/td\u003e\n\u003ctd\u003e14.8 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Current (24 VDC)\u003c\/td\u003e\n\u003ctd\u003e6.1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain Output Voltage\u003c\/td\u003e\n\u003ctd\u003e12 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuxiliary Output Voltage\u003c\/td\u003e\n\u003ctd\u003e5 VDC \/ 3.3 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e12 VDC Output (12 VDC Input)\u003c\/td\u003e\n\u003ctd\u003e13 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e12 VDC Output (24 VDC Input)\u003c\/td\u003e\n\u003ctd\u003e8 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5 VDC Output\u003c\/td\u003e\n\u003ctd\u003e2 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3.3 VDC Output\u003c\/td\u003e\n\u003ctd\u003e2 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCombined Auxiliary Output Power\u003c\/td\u003e\n\u003ctd\u003e10 W maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Protection\u003c\/td\u003e\n\u003ctd\u003eInternal fuse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOvervoltage Protection\u003c\/td\u003e\n\u003ctd\u003e110-120% of nominal output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eDeltaV M-Series Carrier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling\u003c\/td\u003e\n\u003ctd\u003ePassive convection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to +70 deg C (with derating above +60 deg C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5-95%, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.9 kg (per S-Series source text)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHazardous Area Certifications\u003c\/td\u003e\n\u003ctd\u003eATEX, IECEx (per S-Series source text)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What input voltages and output rails are specified for the VE5008? A: The M-Series datasheet specifies 12 VDC (-4% to +5%) or 24 VDC (+\/-20%) input power and 12 VDC, 5 VDC, and 3.3 VDC outputs, with a 10 W combined limit on the 5 VDC and 3.3 VDC rails. A separate section in the provided material references redundant 24 VDC output (5 A per supply, 10 A total); confirm the exact model revision and datasheet for your installation.\u003c\/p\u003e\n\u003cp\u003eQ: Does the VE5008 require forced-air cooling or temperature derating? A: The M-Series specification lists passive convection cooling and an operating range of -40 deg C to +70 deg C with derating above +60 deg C. Check thermal load and cabinet conditions against the applicable DeltaV carrier limits.\u003c\/p\u003e","brand":"Emerson","offers":[{"title":"Default Title","offer_id":51476106674488,"sku":"VE5008","price":200.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/VE5008.jpg?v=1764916654","url":"https:\/\/www.automodulexpert.com\/products\/dc-dc-system-power-supply-module-emerson-deltav-ve5008","provider":"AutoModuleXpert Ltd.","version":"1.0","type":"link"}