This 51402167-100 Industrial Automation Modules was manufactured by HONEYWELL, In Stock, 100% Guaranteed Brand New and Authentic. Link to More Information

 
Manufacturer:
HONEYWELL
Part Number:
51402167-100
Country of Origin:
USA
Condition:
New With Original Package
Shipping Port:
ShangHai, Xiamen
Warranty:
12 Months
 

Honeywell 51402167-100 DCS Module Housing

Configured for high-density hardware execution in Honeywell distributed control platforms, the Honeywell 51402167-100 (51402167-100 Module Housing) provides direct physical/electrical execution for dual-node module mounting and integrated forced-air cooling across process control networks.

Hardware Specifications

Parameter Specification
Model 51402167-100
Brand Honeywell
Origin USA
Weight 0.56 kg
Dimensions 10 x 10 x 2 cm
Operating Temp -20 to +85 deg C
Power Consumption Integrated fan power circuit dependent
Architecture Dual-node housing assembly with fan and cover
Network Protocol Modbus RTU over RS-485 and native DCS bus paths
Mounting Format Rack-mount card-file enclosure

Channel-to-Channel Isolation and DCS Communications

Industrial control cabinets demand rigorous noise immunity and signal integrity across adjacent slot locations. The Honeywell 51402167-100 housing incorporates dedicated channel-to-channel isolation parameters within its backplane interconnections, preventing high-voltage transients on field wiring from coupling into high-speed Modbus RTU or native DCS communications. This physical and electrical shielding layout isolates sensitive processing nodes while maintaining full signal fidelity for 4-20 mA HART loop protocol passes through neighboring I/O assemblies.

Frequently Asked Questions

Q: How does the integrated fan assembly maintain module thermal stability inside enclosed cabinets?

A: The forced-air cooling fan drives continuous airflow directly across installed module heat sinks, dissipating thermal energy and keeping internal semiconductor junction temperatures well within the specified -20 to +85 deg C operating envelope.

Q: What grounding precautions must technicians observe when installing the housing into a control rack?

A: Technicians must bolt the metal enclosure frame directly to the rack rails using star washers to pierce painted surfaces. Connect a heavy-gauge copper grounding strap from the chassis earth stud directly to the main cabinet ground bar to establish a low-impedance path for static charge dissipation.

Field Installation Guidelines

Mount the chassis housing securely into the standard equipment rack using all four corner mounting holes. Verify that top and bottom ventilation paths remain unobstructed by wiring ducts or structural chassis members to ensure free convection and fan exhaust flow.

Route RS-485 serial cables and system bus lines through separate cable raceways away from AC power lines and high-current relay outputs. Terminate cable shields at a single cabinet earth point to eliminate circulating ground loop currents. Prior to extracting or inserting modules within the dual-node housing, isolate all cabinet power supplies or ensure that local environmental conditions satisfy non-incendive safety standards.

Quick Quotes Receive price & availability FAST from our dedicated customer service team.
Delivery Expedited, Freight, And International Shipping Available.
Condition 100% New with Original Package
Payment We accept American Express, Discover, MasterCard, PayPal, and Visa. Our site is secured by RapidSSL.
Shipping Port ShangHai, Xiamen
Warranty 12 Months
Q: Is Our Pricing Competitive?
A: Yes, we collaborate with over 50 countries worldwide. As a top supplier in China, we offer significant discounts based on market trends.
Q: What Is the Warranty Period?
A: All our new and original products come with a standard one-year warranty.
Q: What Payment Methods Do We Accept?
A: We require 100% T/T (Telegraphic Transfer) payment before shipping. For items with a lead time, a 30% deposit is needed upfront, and the remaining 70% is due before shipping. If you have a representative in China, you can arrange an RMB transfer through them.
Q: What Shipping Methods Do We Use?
A: We primarily use FedEx, DHL, UPS, and BRE for shipping. If you have an account with any of these carriers, you can handle shipping directly. We also offer free shipping to China-based freight forwarders.
Q: What Is Our Delivery Time?
A: Delivery usually takes 1-3 days after receiving the initial payment. For items with a lead time, shipping will occur according to the specified schedule.
Q: How Do We Package the Goods?
A: We ensure safe packaging with multiple layers of protection. Products are first placed in their original boxes and sealed with labels. A layer of bubble wrap is then added for collision protection during transit. Finally, the items are packed securely in durable boxes.
Q: How Can Customers Contact Us and Request a Quote?
A: You can reach out to us via email, WhatsApp, WeChat, Skype, or your preferred communication platform. Contact us with your needs, and we'll provide a prompt, customized quote.
 

Recently Viewed

Express Shipping icon
Express Shipping
Rapid delivery for your urgent requirements.
Large stock icon
Extensive Inventory
Large stock for immediate dispatch.
Quality Assurance Icon
Quality Assurance
Authentic, top-grade PLC & DCS components.
Global Service icon
Global Service
Supporting clients worldwide with dependable service.