{"product_id":"digital-i-o-module-yokogawa-f3wd64-3p-k2","title":"Digital I\/O Module Yokogawa F3WD64-3P\/K2","description":"\u003ch3\u003e\u003cstrong\u003eProduct Description\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe F3WD64-3P\/K2 is an advanced, high-density signal interface designed for the Yokogawa FA-M3 \"Range-Free\" controller series. By integrating 32 digital inputs and 32 digital outputs into a single-slot housing, this module significantly reduces the physical footprint required in control cabinets while maximizing channel availability. The unit is engineered for high-speed response times, making it ideal for discrete manufacturing processes where timing is critical.\u003c\/p\u003e\n\u003cp\u003eFeaturing the K2 specification, this module is optimized for streamlined connectivity with specific terminal configurations, ensuring secure and efficient wiring. Every channel is protected by photocoupler isolation, which effectively shields the internal PLC logic from field-side electrical noise and transient voltage spikes. Whether managing sensor arrays or driving actuator banks, the F3WD64-3P\/K2 provides the industrial-grade reliability expected of Japanese-engineered automation hardware.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eF3WD64-3P\/K2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFA-M3 \/ FA-M3V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTotal Channel Count\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e64 Points (32-ch Input \/ 32-ch Output)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIsolation Technology\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePhotocoupler-based galvanic isolation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Section\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32 Channels, 24 V DC (Supports Sink or Source wiring)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Input Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTypically 4.1 mA per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Section\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32 Channels, Transistor outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Load Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12 V to 24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Load Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.1 A per point (Common limitations apply)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWiring Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eK2 Configuration (High-density connector type)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInternal Current Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e140 mA (at 5 V DC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStatus Indicators\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePer-channel LED monitoring for I\/O logic states\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication Scenarios\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eElectronic Component Assembly\u003c\/strong\u003e: Managing high-volume sensor feedback and solenoid control in pick-and-place machinery.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAutomated Warehouse Systems\u003c\/strong\u003e: Coordinating multiple conveyor interlocks and optical gates within a compact enclosure.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOEM Machinery\u003c\/strong\u003e: Providing a cost-effective, single-module solution for machines with high I\/O requirements but limited rack space.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch4\u003e\u003cem\u003eDoes the F3WD64-3P\/K2 support both NPN and PNP sensors?\u003c\/em\u003e\u003c\/h4\u003e\n\u003cp\u003eYes, the input section is configurable for both sink and source wiring, allowing for flexible integration with various industrial sensor types.\u003c\/p\u003e\n\u003ch4\u003e\u003cem\u003eWhat type of connector is required for the K2 version?\u003c\/em\u003e\u003c\/h4\u003e\n\u003cp\u003eThe K2 designation typically requires a specific high-density 40-pin or similar multi-pin connector. It is recommended to use pre-fabricated Yokogawa cables for the most reliable connection.\u003c\/p\u003e","brand":"YOKOGAWA","offers":[{"title":"Default Title","offer_id":51840029819192,"sku":"F3WD64-3P\/K2","price":188.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/F3WD64-3PK2.jpg?v=1772160015","url":"https:\/\/www.automodulexpert.com\/products\/digital-i-o-module-yokogawa-f3wd64-3p-k2","provider":"AutoModuleXpert Ltd.","version":"1.0","type":"link"}