{"product_id":"digital-output-module-adv551-p63-d5a00-yokogawa","title":"Digital Output Module ADV551-P63\/D5A00 Yokogawa","description":"\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYokogawa ADV551-P63\/D5A00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ehigh-density 32-channel digital output module\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edesigned for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCENTUM VP Integrated Production Control System\u003c\/strong\u003e. Engineered for applications that require more than simple on\/off control, it supports\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003epulse width modulation (PWM)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003etime-proportional output\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efunctions, enabling precise control of devices such as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003esolid-state relays\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003edosing valves\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eBuilt for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eharsh industrial environments\u003c\/strong\u003e, the module includes\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eG3-rated conformal coating\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor protection against corrosive gases and operates over a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e−20°C to +70°C temperature range\u003c\/strong\u003e. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eD5A00 option\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eintegrates the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eATD5A-00 adapter\u003c\/strong\u003e, allowing all 32 channels to connect via a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003esingle KS cable\u003c\/strong\u003e, reducing wiring complexity and cabinet footprint.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eADV551\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFull Order Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eADV551-P63\/D5A00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Channels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCurrent sink (Transistor contact)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl Functions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePulse Width \/ Time-Proportional Output (Suffix P)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Load Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Load Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 mA per channel @ 26.4 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIsolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 kV AC, 1 min (signal to system)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommon Group Isolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 V AC, 1 min (per 16-channel group)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVisual Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLocal status display (Suffix 6)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnvironmental Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eISA G3 corrosive gas protection (Suffix 3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e−20°C to +70°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterface Adapter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eATD5A-00 (KS cable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch2\u003eModule Feature Breakdown\u003c\/h2\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAdvanced Output Modes\u003c\/strong\u003e\u003cbr\u003ePulse width and time-proportional outputs enable precise duty-cycle control for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003etemperature regulation\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003echemical injection\u003c\/strong\u003e.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCorrosion Resistance\u003c\/strong\u003e\u003cbr\u003eG3 conformal coating protects against corrosive industrial atmospheres, suitable for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ewastewater treatment, paper mills, and refineries\u003c\/strong\u003e.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eStreamlined Wiring\u003c\/strong\u003e\u003cbr\u003ePre-installed\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eATD5A-00 adapter (D5A00 option)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eallows a single KS cable to handle all 32 channels, reducing wiring complexity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eIndustrial Applications\u003c\/h2\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProportional Heating Control\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e– Driving SSRs for industrial furnaces and heaters.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eChemical Dosing\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e– Pulse-width control of solenoid metering pumps.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eValve Manifold Management\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e– High-density actuation of solenoid valves in skids.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHarsh Environments\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e– Reliable operation under corrosive or extreme temperature conditions.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnical FAQ\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What distinguishes the ADV551-P63\/D5A00 from the standard ADV551?\u003c\/strong\u003e\u003cbr\u003eA: The P63\/D5A00 variant supports\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003epulse-width\/time-proportional output\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eG3 corrosion protection\u003c\/strong\u003e, whereas standard versions only provide basic discrete switching with standard temperature ratings.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How are the 32 channels grouped for wiring?\u003c\/strong\u003e\u003cbr\u003eA: Channels are arranged in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003etwo 16-channel groups\u003c\/strong\u003e, each with a negative (-) common, electrically isolated from the other by 500 V AC.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can this module drive inductive loads?\u003c\/strong\u003e\u003cbr\u003eA: Yes, up to 100 mA per channel. For larger solenoids or inductive devices,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eexternal suppression or interposing relays\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eare recommended to prevent transistor wear.\u003c\/p\u003e","brand":"YOKOGAWA","offers":[{"title":"Default Title","offer_id":51687944782136,"sku":"ADV551-P63\/D5A00","price":188.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/ADV551-P13.jpg?v=1770083113","url":"https:\/\/www.automodulexpert.com\/products\/digital-output-module-adv551-p63-d5a00-yokogawa","provider":"AutoModuleXpert Ltd.","version":"1.0","type":"link"}