{"product_id":"digital-output-module-foxboro-p0913rc-ob-p0913mrc","title":"Digital Output Module | Foxboro P0913RC-OB P0913MRC","description":"\u003ch2\u003eFoxboro P0913RC-OB P0913MRC Digital Output Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eFoxboro P0913RC-OB \/ P0913MRC\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eP0913RC-OB\u003c\/strong\u003e Digital Output Module, operates as a dedicated hardware component for configurable signal routing and actuator control within Foxboro I\/A Series distributed control systems. The module set processes digital command instructions from the central processor to regulate analog-compatible control loops, translating host logic states into precise voltage or current output levels.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cp\u003eThe subsystem relies on paired hardware assemblies to execute termination and signal conversion tasks:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eP0913RC-OB\u003c\/strong\u003e: Acts as the primary digital output processing module handling command state decoding.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eP0913MRC\u003c\/strong\u003e: Serves as the companion termination assembly dedicated to physical field wiring and signal loop distribution.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eP0913RC-OB \/ P0913MRC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eFoxboro\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e6.3 x 7.4 x 9.1 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e4.2 W nominal from system bus rails\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eDigital Output Module Set\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Ranges\u003c\/td\u003e\n\u003ctd\u003eConfigurable 0-10 V and 4-20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure Profile\u003c\/td\u003e\n\u003ctd\u003eCompact industrial modular assembly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eChannel-to-Channel Isolation \u0026amp; 4-20 mA HART Loop Protocols\u003c\/h3\u003e\n\u003cp\u003eThe internal architecture incorporates robust channel-to-channel isolation barriers to eliminate ground loops and prevent high-voltage electrical transients from feeding back into the backplane bus. By integrating 4-20 mA HART loop protocols, the unit allows superimposed digital diagnostic communications alongside standard analog control signals. This design ensures signal integrity when driving proportional valves, actuators, and remote relay interfaces across complex industrial cabling layouts.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How does the module handle output states during a controller communication fault?\u003c\/p\u003e\n\u003cp\u003eA: Upon losing connection with the primary controller node, internal watchdog timers force output channels into pre-configured fail-safe states to prevent erratic field device behavior.\u003c\/p\u003e\n\u003cp\u003eQ: Can the termination module be replaced without powering down the entire cabinet rack?\u003c\/p\u003e\n\u003cp\u003eA: Online replacement is restricted by the backplane power architecture; technicians must isolate system power to the specific slot before extracting or inserting hardware components.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eEngineers must follow established electrical and mechanical standards during site deployment:\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eSecure the assembly onto a rigid, grounded mounting plate within a protective control enclosure, ensuring proper alignment with the backplane connectors.\u003c\/li\u003e\n\u003cli\u003eRoute low-level control loops through dedicated metal conduits, keeping them physically separated from high-voltage alternating current power lines to minimize induced noise.\u003c\/li\u003e\n\u003cli\u003eTerminate all shielded signal cable drains directly to the designated enclosure grounding bar using low-impedance grounding clips to maintain electromagnetic compatibility.\u003c\/li\u003e\n\u003cli\u003eVerify all terminal block screw connections to ensure secure mechanical contact before applying operating power to the system.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"FOXBORO","offers":[{"title":"Default Title","offer_id":51286442672440,"sku":"P0913RC-OB\/P0913MRC","price":230.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/P0913RC-OBP0913MRC1.jpg?v=1761636128","url":"https:\/\/www.automodulexpert.com\/products\/digital-output-module-foxboro-p0913rc-ob-p0913mrc","provider":"AutoModuleXpert Ltd.","version":"1.0","type":"link"}