{"product_id":"digital-output-module-yokogawa-adv551-p50-s2","title":"Digital Output Module Yokogawa ADV551-P50 S2","description":"\u003ch3\u003eTechnical Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eADV551-P50 S2\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ehigh-density discrete output module\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYokogawa CENTUM VP \/ CS 3000\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eseries. It provides\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e32 transistor-based current-sink outputs\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ewith integrated\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003epulse width and time-proportional control\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eAs a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eStyle 2 (S2) hardware revision\u003c\/strong\u003e, it features improved thermal performance and component reliability for 24\/7 industrial operations. Its compact, high-density design makes it ideal for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eoptimizing I\/O rack space\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ein control cabinets.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Channels\u003c\/td\u003e\n\u003ctd\u003e32 discrete outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eADV551-P50 S2 (Style 2 hardware)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Format\u003c\/td\u003e\n\u003ctd\u003eCurrent Sink (NPN transistor)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Load Voltage\u003c\/td\u003e\n\u003ctd\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Switching Voltage\u003c\/td\u003e\n\u003ctd\u003e30 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Load Current\u003c\/td\u003e\n\u003ctd\u003e100 mA per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time\u003c\/td\u003e\n\u003ctd\u003e≤ 16 ms (standard status transition)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpecial Functions\u003c\/td\u003e\n\u003ctd\u003ePulse Width \/ Time-Proportional Output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003e500 V AC (Output-to-System)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Bus Power\u003c\/td\u003e\n\u003ctd\u003e500 mA max at 5 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhysical Dimensions\u003c\/td\u003e\n\u003ctd\u003e5.1 cm × 10.7 cm × 12.7 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnectivity\u003c\/td\u003e\n\u003ctd\u003ePressure clamp terminals or KS cables (e.g., AKB331 series)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Speed Transistor Switching:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProvides rapid, reliable output control for small actuators and indicators.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePulse Width \/ Time-Proportional Output:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAllows modulation of duty cycles for heating, dosing, or valve control.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eS2 Hardware Revision:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEnhanced internal circuitry and heat management for long-term operation in dense I\/O nests.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCompact Footprint:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e32 outputs in a single slot, maximizing rack efficiency.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFlexible Cabling:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCompatible with dedicated KS cables or standard pressure clamp terminals.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eIndustrial Applications\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSolenoid Valve Actuation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePrecision control of pilot valves in pneumatic manifolds.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTime-Proportional Heating:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDriving SSRs for regulated power output in temperature-controlled vessels.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSystem Signaling:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eHandshaking and status outputs to PLCs or ESD systems.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperator Interface Control:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDriving lamps and alarms on hardwired control consoles.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical FAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the advantage of the Style 2 (S2) hardware?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eS2 modules offer improved thermal performance, updated internal components, and higher reliability compared to Style 1 modules, making them ideal for high-density I\/O installations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this module require an external power supply?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eYes. Internal logic uses 5 V DC from the system bus, but field-side devices require an external 24 V DC power source.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eWhat cabling is recommended?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eDepending on installation, either\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003epressure clamp terminals\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eor\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ededicated KS cables\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(e.g., AKB331 series) can be used to connect to external terminal boards, ensuring clean wiring in high-density setups.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"YOKOGAWA","offers":[{"title":"Default Title","offer_id":51683660759352,"sku":"ADV551-P50 S2","price":188.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/ADV551-P50_S21.jpg?v=1770001408","url":"https:\/\/www.automodulexpert.com\/products\/digital-output-module-yokogawa-adv551-p50-s2","provider":"AutoModuleXpert Ltd.","version":"1.0","type":"link"}