{"product_id":"do232-bachmann-00009003-00-m200-digital-output-module","title":"DO232 BACHMANN 00009003-00 M200 Digital Output Module","description":"\u003ch2\u003eBACHMANN DO232 Digital Output Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eBACHMANN DO232\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eDO232\u003c\/strong\u003e Digital Output Module, operates as a dedicated hardware component for driving digital signal receivers and field actuators within Bachmann M200 Automation System platforms.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eModel Designation\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e00009003-00\u003c\/td\u003e\n\u003ctd\u003eDO232\u003c\/td\u003e\n\u003ctd\u003eStandard 32-Channel 24 VDC Digital Output Module\u003c\/td\u003e\n\u003ctd\u003e-30 deg C to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e00016414-00\u003c\/td\u003e\n\u003ctd\u003eDO232 CC\u003c\/td\u003e\n\u003ctd\u003eColdClimate 32-Channel 24 VDC Digital Output Module\u003c\/td\u003e\n\u003ctd\u003eExtended environmental rating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eDO232 (Part No. 00009003-00)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBACHMANN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eAustria\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.32 kg (0.70 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eCompact M1\/M200 standard module width\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-30 deg C to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePowered via 24 VDC backplane \u0026amp; field bus supplies\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Channels\u003c\/td\u003e\n\u003ctd\u003e32 digital outputs (sinking\/sourcing relay, lamp, valve loads)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Current\u003c\/td\u003e\n\u003ctd\u003e1 A max per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Grouping\u003c\/td\u003e\n\u003ctd\u003e2 isolated groups (Channels 1-16 \/ Channels 17-32)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGroup Current Limit\u003c\/td\u003e\n\u003ctd\u003e8 A max total current per group\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSwitching Delay\u003c\/td\u003e\n\u003ctd\u003e0 -\u0026gt; 1: ~80 us \/ 1 -\u0026gt; 0: ~250 us (at 1 A resistive load)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiagnostics\u003c\/td\u003e\n\u003ctd\u003eIntegrated short-circuit, cable break, and thermal overload detection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Isolation\u003c\/td\u003e\n\u003ctd\u003e500 V galvanic isolation between field logic and backplane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDeterministic Network Scaling \u0026amp; Output Execution\u003c\/h3\u003e\n\u003cp\u003eThe output module executes high-speed switching tasks managed across the backplane bus communication velocity Licences network, ensuring precise command execution for solenoid valves, contactors, and indicator banks. Dynamic I\/O density scaling allows 32 high-current field loads to pair with a single controller slot without imposing continuous CPU overhead. Built-in diagnostic monitoring continuously reports wire breakage and short-circuit fault conditions back to the host application while maintaining full firmware flash compatibility across backplane processing racks.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How are the 32 output channels divided into isolated electrical power groups?\u003c\/p\u003e\n\u003cp\u003eA: The module splits output channels into two distinct groups (Channels 1 to 16 and Channels 17 to 32), each accepting an independent 24 VDC external supply rated up to 8 A total per bank.\u003c\/p\u003e\n\u003cp\u003eQ: What diagnostic protection mechanisms safeguard individual output channels against field faults?\u003c\/p\u003e\n\u003cp\u003eA: Internal monitoring circuits evaluate channel state conditions continuously, automatically shutting down drivers affected by short circuits, thermal overloads, or open-circuit cable breaks while illuminating channel diagnostic LEDs.\u003c\/p\u003e\n\u003cp\u003eQ: What front connection accessories are available for field wiring termination?\u003c\/p\u003e\n\u003cp\u003eA: Field connections accept either the KZ-DO232 B+C cage clamp terminal set (Part No. 00012006-50) or the SV-DO232 B+C screw terminal set (Part No. 00010868-50).\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eMount the module on the standard M200 backplane chassis inside an IP54-rated metal enclosure. Ensure proper connection of separate 24 VDC auxiliary power feeds for Channel Groups 1-16 and 17-32, verifying external fast-acting inline fusing does not exceed the 8 A per-group ceiling limit. De-energize all field power sources prior to plugging or unplugging terminal blocks. Terminate cable shielding at the low-impedance grounding rail using standard grounding clamps to prevent inductive field transients from back-feeding into control circuitry.\u003c\/p\u003e","brand":"BACHMANN","offers":[{"title":"Default Title","offer_id":52895024546104,"sku":"DO232","price":185.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/264.1.jpg?v=1788329336","url":"https:\/\/www.automodulexpert.com\/products\/do232-bachmann-00009003-00-m200-digital-output-module","provider":"AutoModuleXpert Ltd.","version":"1.0","type":"link"}