{"product_id":"ds200exdeg1ada-excitation-control-board-ge","title":"DS200EXDEG1ADA Excitation Control Board GE","description":"\u003cp\u003eConfigured for excitation regulation and control signal processing in turbine management platforms, the \u003cstrong\u003eGE DS200EXDEG1ADA\u003c\/strong\u003e (\u003cstrong\u003eDS200EXDEG1ADA\u003c\/strong\u003e Excitation Control Board) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cp\u003eThe DS200EXDEG1ADA is a specific hardware revision within the EXDE board series. This board features a fixed physical layout including two 34-pin connectors and two 10-pin connectors for signal interfacing. Hardware variations for this model are determined by the revision code; the \"G1ADA\" suffix identifies the primary assembly design for excitation control applications.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eDS200EXDEG1ADA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.5kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard PCB form factor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnectivity\u003c\/td\u003e\n\u003ctd\u003e(2) 34-pin, (2) 10-pin connectors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVisual Indicators\u003c\/td\u003e\n\u003ctd\u003e5 LED status indicators\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Communication Velocity\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eGE DS200EXDEG1ADA\u003c\/strong\u003e operates as a critical component within the excitation control loop. The board utilizes an integrated network of capacitors and test points to maintain signal stability and facilitate accurate voltage regulation. Communication between the board and the host excitation system occurs via high-density pin connectors, requiring consistent backplane bus communication velocity to process regulator commands. The five onboard indicator LEDs provide immediate visual feedback regarding the operational state of the board's internal logic and signal processing circuits. Mismatched firmware or configuration settings within the control rack can lead to excitation instability or diagnostic faults, necessitating correct seating of all interface cables.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What is the function of the onboard test points on this board?\u003c\/p\u003e\n\u003cp\u003eA: The test points are provided for diagnostic purposes, allowing technicians to verify internal signal voltages, power rails, and loop stability using calibrated measurement equipment without interrupting control signals.\u003c\/p\u003e\n\u003cp\u003eQ: Can the board be installed while the excitation system is active?\u003c\/p\u003e\n\u003cp\u003eA: No. The DS200EXDEG1ADA must be de-energized by isolating all power inputs to the excitation rack before attempting insertion or removal to protect the pins and backplane buffers from electrical damage.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting\u003c\/strong\u003e: Ensure the PCB is properly aligned and seated within the designated slot. Secure the board using existing mounting hardware to maintain electrical continuity with the chassis ground.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnector Integrity\u003c\/strong\u003e: Inspect the two 34-pin and two 10-pin connectors for bent pins or contamination before engagement. Ensure locking mechanisms are secure to prevent intermittent connection failures.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal Shielding\u003c\/strong\u003e: Route signal wiring away from high-current field paths to prevent electromagnetic interference. Use shielded cables for all I\/O connections, terminating the shields at the cabinet grounding bar.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperational Monitoring\u003c\/strong\u003e: Upon power-up, verify that the five status LEDs align with the expected boot sequence for the excitation control system. If an error LED illuminates, refer to the system diagnostic manual for fault code identification.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE FANUC","offers":[{"title":"Default Title","offer_id":52596564853048,"sku":"DS200EXDEG1ADA","price":220.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/DS200EXDEG1ADA.jpg?v=1782980884","url":"https:\/\/www.automodulexpert.com\/products\/ds200exdeg1ada-excitation-control-board-ge","provider":"AutoModuleXpert Ltd.","version":"1.0","type":"link"}