{"product_id":"ds200expdg3-expansion-board-ge-fanuc","title":"DS200EXPDG3 Expansion Board GE Fanuc","description":"\u003cp\u003eConfigured for I\/O capacity scaling in Mark V Speedtronic turbine control platforms, the \u003cstrong\u003eGE Fanuc DS200EXPDG3\u003c\/strong\u003e (\u003cstrong\u003eDS200EXPDG3\u003c\/strong\u003e Expansion Board) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eDS200EXPDG3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard Mark V PCB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 deg C to 55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity Tolerance\u003c\/td\u003e\n\u003ctd\u003e0% to 95% RH (non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Handling\u003c\/td\u003e\n\u003ctd\u003eDigital and analog expansion\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProfinet \/ EtherNet\/IP Deterministic Networks\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eGE Fanuc DS200EXPDG3\u003c\/strong\u003e functions as a primary interface board for extending signal processing capabilities within the Mark V control rack. The module facilitates the integration of additional I\/O signals, ensuring that data throughput maintains backplane bus communication velocity requirements. Firmware flash compatibility is strictly managed by the Speedtronic host controller; mismatched firmware versions between the expansion module and the central processor will result in I\/O scan errors or communication failures. The board incorporates deterministic signal management to support redundant architecture configurations, ensuring that both digital and analog expansion signals are processed in accordance with the system's defined scan cycle.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does this board support hot-swapping within the Mark V rack?\u003c\/p\u003e\n\u003cp\u003eA: No. The board must be completely isolated from the 24 VDC control power before insertion or extraction from the rack to prevent electrical transients from damaging the high-density pin connectors or backplane circuitry.\u003c\/p\u003e\n\u003cp\u003eQ: What is the purpose of the onboard diagnostic LED indicators?\u003c\/p\u003e\n\u003cp\u003eA: The onboard LEDs provide real-time status monitoring of the board's operational health, signal activity, and power state, allowing for rapid identification of localized hardware or communication faults.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting\u003c\/strong\u003e: Ensure the board is firmly seated into the Mark V backplane slot. Secure the module using the built-in locking mechanisms to guarantee consistent pin contact and chassis ground bonding.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring\u003c\/strong\u003e: All expansion I\/O signals should be connected using shielded cabling. Ensure the drain wire is connected to the cabinet's designated earth ground to minimize noise interference on analog signal paths.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal Integrity\u003c\/strong\u003e: Separate expansion signal wiring from high-current AC or motor control cables to prevent inductive crosstalk.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Protection\u003c\/strong\u003e: Verify that the operating environment is maintained within the 0 deg C to 55 deg C range and that humidity levels do not exceed the 95% non-condensing limit, as moisture can lead to corrosion on the exposed high-density connectors.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE FANUC","offers":[{"title":"Default Title","offer_id":52596544667960,"sku":"DS200EXPDG3","price":220.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/DS200EXDEG1ADA.jpg?v=1782980884","url":"https:\/\/www.automodulexpert.com\/products\/ds200expdg3-expansion-board-ge-fanuc","provider":"AutoModuleXpert Ltd.","version":"1.0","type":"link"}