{"product_id":"ds200tbqbg1a-input-termination-module-ge","title":"DS200TBQBG1A Input Termination Module GE","description":"\u003cp\u003eConfigured for signal routing within Mark V Speedtronic turbine control cabinets, the \u003cstrong\u003eGE DS200TBQBG1A\u003c\/strong\u003e (\u003cstrong\u003eDS200TBQBG1A\u003c\/strong\u003e Input Termination Module) provides direct physical\/electrical execution. The board serves as the primary terminal junction for incoming field signals, facilitating the transition between external instrumentation and the system backplane.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eDS200TBQBG1A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGeneral Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard Mark V PCB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-30 to 65 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eLogic Level DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eI\/O Capacity\u003c\/td\u003e\n\u003ctd\u003eMulti-channel termination\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e4-20 mA HART Loop Protocol and Signal Conditioning\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eDS200TBQBG1A\u003c\/strong\u003e utilizes dedicated signal paths designed to support 4-20 mA HART loop protocol standards across turbine monitoring loops. Its layout minimizes parasitic capacitance between adjacent terminals, ensuring high fidelity for analog feedback signals. The module incorporates localized filtering to maintain channel-to-channel isolation, preventing common-mode noise from affecting the precision of the input data processed by the Mark V controller. All termination points are engineered to withstand the thermal cycling inherent in turbine control environments without degrading contact resistance.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Are there specific torque requirements for the terminal connections on this module?\u003c\/p\u003e\n\u003cp\u003eA: Yes. All field wiring terminals should be tightened to the specific torque values mandated by the Mark V installation manual to ensure reliable mechanical contact and prevent thermal expansion issues.\u003c\/p\u003e\n\u003cp\u003eQ: Does the DS200TBQBG1A require an external power supply for signal conditioning?\u003c\/p\u003e\n\u003cp\u003eA: No. The board is a passive termination component that derives its necessary logic-level power through the backplane connection to the rack, though it supports the transmission of loop-powered 4-20 mA signals.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eVerify that the Mark V control rack is fully de-energized and follows site-specific lockout\/tagout protocols before accessing the termination cabinet.\u003c\/li\u003e\n\u003cli\u003eAlign the board precisely with the rack mounting guides and secure it using all designated mounting hardware to ensure proper chassis grounding.\u003c\/li\u003e\n\u003cli\u003eEnsure that all ribbon cables are routed cleanly through the cabinet wireways to prevent mechanical stress on the board connectors.\u003c\/li\u003e\n\u003cli\u003eVerify the wire gauge of all incoming field signals; terminate wires into the terminal blocks while ensuring that no strands are frayed or exposed.\u003c\/li\u003e\n\u003cli\u003eInspect the board for any residual metallic debris or moisture before closing the cabinet door.\u003c\/li\u003e\n\u003cli\u003eConduct a signal verification test using an external loop calibrator to confirm that the input readings at the controller match the physical signal at the terminal block.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"GE FANUC","offers":[{"title":"Default Title","offer_id":52592694821176,"sku":"DS200TBQBG1A","price":220.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/DS200TBQBG1A.jpg?v=1782892600","url":"https:\/\/www.automodulexpert.com\/products\/ds200tbqbg1a-input-termination-module-ge","provider":"AutoModuleXpert Ltd.","version":"1.0","type":"link"}