{"product_id":"duplexed-bus-repeater-module-yokogawa-ynt512d","title":"Duplexed Bus Repeater Module Yokogawa YNT512D","description":"\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYNT512D\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eduplexed Bus Repeater Module\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edeveloped by Yokogawa for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCENTUM VP\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eProSafe-RS\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003econtrol systems. It extends the reach and maintains the integrity of\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eVnet\/IP or ESB Bus networks\u003c\/strong\u003e. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eduplexed (“D”) design\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eensures continuous communication even if one internal path fails, making it ideal for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003emission-critical industrial environments\u003c\/strong\u003e. Its compact, rugged construction allows deployment in high-density marshaling cabinets without compromising reliability.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Number\u003c\/td\u003e\n\u003ctd\u003eYNT512D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eDuplexed Bus Repeater Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRedundancy\u003c\/td\u003e\n\u003ctd\u003eDual-redundant communication paths\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e10.3 cm × 5.1 cm × 5.4 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMass\u003c\/td\u003e\n\u003ctd\u003e8.0 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterface Compatibility\u003c\/td\u003e\n\u003ctd\u003eYokogawa high-speed proprietary control buses\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStatus Indicators\u003c\/td\u003e\n\u003ctd\u003eLED diagnostics for power and bus activity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation\u003c\/td\u003e\n\u003ctd\u003ePlug-in module for compatible baseplates\/nests\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eManufactured in the United States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch2\u003eIndustrial Application Scenarios\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYNT512D\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis commonly deployed in:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eLarge-scale Distributed Control Systems (DCS)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ewhere control stations are separated by long distances\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower generation and petrochemical plants\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003erequiring fault-tolerant communication backbones\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eElectrically noisy environments\u003c\/strong\u003e, providing isolation between bus segments to prevent signal degradation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eIts duplexed architecture ensures that\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003emission-critical safety loops remain operational\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eeven if one internal path encounters a failure.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003e1. What is the advantage of the 'D' version over the standard YNT512?\u003c\/strong\u003e\u003cbr\u003eThe YNT512D provides\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003einternal hardware redundancy\u003c\/strong\u003e, allowing a \"bumpless\" transfer of data if one circuit fails, preventing system-wide communication loss.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e2. Does this module require a separate power supply?\u003c\/strong\u003e\u003cbr\u003eNo. The YNT512D draws power directly from the backplane or nest in which it is installed, simplifying cabinet wiring and minimizing additional infrastructure.\u003c\/p\u003e","brand":"YOKOGAWA","offers":[{"title":"Default Title","offer_id":51797454487864,"sku":"YNT512D","price":188.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/YNT512D.jpg?v=1770966548","url":"https:\/\/www.automodulexpert.com\/products\/duplexed-bus-repeater-module-yokogawa-ynt512d","provider":"AutoModuleXpert Ltd.","version":"1.0","type":"link"}