{"product_id":"eddy-current-sensor-system-emerson-con021-pr6423-010-100","title":"Eddy Current Sensor System | Emerson CON021+PR6423\/010-100","description":"\u003ch2\u003eEmerson CON021+PR6423\/010-100 Eddy Current Displacement Sensor System\u003c\/h2\u003e\n\u003cp\u003eThe Emerson \u003cstrong\u003eCON021+PR6423\/010-100\u003c\/strong\u003e is a non-contact eddy current displacement measurement assembly combining a PR6423\/010-100 proximity probe with a CON021 signal converter. It measures shaft vibration, radial displacement, axial position, and eccentricity on rotating equipment without mechanical contact. Specifications list an 8 mm probe tip diameter, a 2.0 mm standard measuring range, 0–20 kHz (-3 dB) converter frequency response, and -35 deg C to +180 deg C probe operating temperature.\u003c\/p\u003e\n\u003ch3\u003eSensing and Signal Conditioning\u003c\/h3\u003e\n\u003cp\u003eNon-contact eddy current sensing detects gap distance changes between the probe tip and a conductive shaft surface to track shaft vibration, axial displacement, and position without mechanical wear. Source notes indicate targets optimized for ferromagnetic steel such as 42CrMo4 (AISI 4140), while the CON021 converter powers probe excitation and outputs a conditioned electrical signal for monitoring and protection systems.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eProbe and Target:\u003c\/strong\u003e Uses an 8 mm non-contact eddy current probe tuned for ferromagnetic steel targets such as 42CrMo4 (AISI 4140).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRange and Linearity:\u003c\/strong\u003e Provides a 2.0 mm standard measuring range with CON021 configuration and less than or equal to 1.0% linearity error over the standard PR6423 range.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBandwidth:\u003c\/strong\u003e Converter frequency response spans 0–20 kHz (-3 dB) for capturing dynamic shaft motion.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical and Environmental Ratings\u003c\/h3\u003e\n\u003cp\u003eConverter supply voltage is listed as -23 to -32 VDC or -21 to -32 VDC depending on output range, paired with -4 to -20 VDC or -2 to -18 VDC output ranges and IP20 converter protection over -30 deg C to +100 deg C. The probe is rated for -35 deg C to +180 deg C operation with an IP66 enclosure rating noted in the probe overview.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eConverter Supply and Output:\u003c\/strong\u003e Supply is -23 to -32 VDC or -21 to -32 VDC depending on output range (-4 to -20 VDC or -2 to -18 VDC).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature and Ingress Ratings:\u003c\/strong\u003e Probe operates from -35 deg C to +180 deg C (IP66 noted in probe overview), while the converter is rated for -30 deg C to +100 deg C with IP20 protection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCON021+PR6423\/010-100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eEmerson (EPRO)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eEddy Current Displacement Sensor System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor Type\u003c\/td\u003e\n\u003ctd\u003eNon-contact eddy-current proximity probe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe Series\u003c\/td\u003e\n\u003ctd\u003ePR6423\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe Tip Diameter\u003c\/td\u003e\n\u003ctd\u003e8 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard Measuring Range\u003c\/td\u003e\n\u003ctd\u003e2.0 mm with standard CON021 configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLinearity Error\u003c\/td\u003e\n\u003ctd\u003eLess than or equal to 1.0% for standard PR6423 range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConverter Frequency Response\u003c\/td\u003e\n\u003ctd\u003e0–20 kHz (-3 dB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConverter Supply Voltage\u003c\/td\u003e\n\u003ctd\u003e-23 to -32 VDC or -21 to -32 VDC, depending on output range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConverter Output\u003c\/td\u003e\n\u003ctd\u003e-4 to -20 VDC or -2 to -18 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConverter Protection\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConverter Operating Temperature\u003c\/td\u003e\n\u003ctd\u003e-30 deg C to +100 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe Operating Temperature\u003c\/td\u003e\n\u003ctd\u003e-35 deg C to +180 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003cp\u003eFrequently Asked Questions\u003c\/p\u003e\n\u003cp\u003eQ: What measuring range, linearity, and frequency bandwidth apply to the CON021+PR6423\/010-100? A: Specifications list a 2.0 mm standard measuring range with CON021 configuration, linearity error less than or equal to 1.0% for the standard PR6423 range, and a 0–20 kHz (-3 dB) converter frequency response. Verify shaft target material and monitoring input scaling during installation and calibration.\u003c\/p\u003e\n\u003cp\u003eQ: How do the converter supply voltage and output range relate? A: The converter supply is -23 to -32 VDC or -21 to -32 VDC depending on output range, with output options of -4 to -20 VDC or -2 to -18 VDC. Confirm the exact converter configuration and power supply margin for your monitoring channel.\u003c\/p\u003e\n\u003cp\u003eQ: What temperature ratings apply to the probe and converter? A: The probe operating temperature is -35 deg C to +180 deg C, and the converter operating temperature is -30 deg C to +100 deg C with IP20 protection. Check local probe-tip and cabinet ambient temperatures before deployment.\u003c\/p\u003e","brand":"EPRO","offers":[{"title":"Default Title","offer_id":51483802075448,"sku":"CON021+PR6423\/010-100","price":256.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/CON021_PR6423010-1002.jpg?v=1765157825","url":"https:\/\/www.automodulexpert.com\/products\/eddy-current-sensor-system-emerson-con021-pr6423-010-100","provider":"AutoModuleXpert Ltd.","version":"1.0","type":"link"}