{"product_id":"emerson-5x00106g02-ovation-analog-input-module","title":"Emerson 5X00106G02 Ovation Analog Input Module","description":"\u003ch2\u003eEmerson 5X00106G02 Ovation Analog Input Module\u003c\/h2\u003e\n\u003cp\u003eConfigured for high-accuracy analog data acquisition in Ovation Distributed Control System networks, the \u003cstrong\u003eEmerson 5X00106G02\u003c\/strong\u003e (\u003cstrong\u003e5X00106G02\u003c\/strong\u003e Analog Input Module) provides direct physical\/electrical execution. It digitizes continuous field transmitter currents and voltages for real-time controller processing.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e5X00106G02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eEmerson\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.45 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard Ovation I\/O Module Form Factor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eStandard Ovation Backplane Bus Powered\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Type\u003c\/td\u003e\n\u003ctd\u003eAnalog (4-20 mA \/ Voltage)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Interface\u003c\/td\u003e\n\u003ctd\u003eOvation Controller Bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConversion Tech\u003c\/td\u003e\n\u003ctd\u003eHigh-resolution A\/D conversion\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eChannel Isolation and HART Protocol Processing\u003c\/h3\u003e\n\u003cp\u003eThe module incorporates robust signal-conditioning architecture designed to reduce common-mode electrical noise and maintain high signal fidelity across processing channels. Integrated channel-to-channel isolation safeguards the internal Ovation backplane bus against voltage spikes and ground loops coming from field instrumentation. Supporting standard 4-20 mA current loops, the input circuitry delivers high-resolution analog-to-digital conversion, ensuring high measurement precision for critical closed-loop control tasks.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How does the module maintain measurement integrity in electrically noisy industrial environments?\u003c\/p\u003e\n\u003cp\u003eA: The module relies on internal signal conditioning and high-resolution A\/D conversion circuits to filter out EMI and common-mode noise before transmitting digital values to the local controller bus.\u003c\/p\u003e\n\u003cp\u003eQ: What precautions are required when installing or removing the module from the Ovation I\/O chassis?\u003c\/p\u003e\n\u003cp\u003eA: Technicians must ensure that field terminal blocks are isolated or unpowered where necessary, and observe standard ESD handling procedures before mounting the module onto the backplane assembly.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eMount the module directly into the designated Ovation I\/O chassis slot until the locking latches engage fully. Verify that all field wiring for 4-20 mA loops utilizes twisted shielded pairs grounded at a single point to mitigate ground-loop risks. Maintain a minimum of 5 full thread engagements on NPT conduit fittings to ensure proper strain relief and mechanical protection. Route low-voltage signal cables away from high-voltage AC lines to prevent magnetic coupling.\u003c\/p\u003e","brand":"OVATION","offers":[{"title":"Default Title","offer_id":51217318183224,"sku":"5X00106G02","price":190.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/603_5977d476-9a6a-4260-9daf-cd1ef1be202b.jpg?v=1789699082","url":"https:\/\/www.automodulexpert.com\/products\/emerson-5x00106g02-ovation-analog-input-module","provider":"AutoModuleXpert Ltd.","version":"1.0","type":"link"}