{"product_id":"emerson-a0760gp-icp-industrial-accelerometer-vibration-sensor","title":"Emerson A0760GP ICP Industrial Accelerometer Vibration Sensor","description":"\u003ch2\u003eEmerson A0760GP Industrial Accelerometer\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eEmerson A0760GP\u003c\/strong\u003e is a general-purpose ICP piezoelectric accelerometer in the AMS Machinery Health line for machinery vibration monitoring and condition-based maintenance on rotating equipment such as motors, pumps, compressors, turbines, and generators. It provides a 100 mV\/g sensitivity across 0.5-10,000 Hz within a +\/-50 g measurement range, housed in a hermetically sealed stainless steel body with a 2-pin MIL-C-5015 connector and 1\/4-28 UNF-2B mounting thread.\u003c\/p\u003e\n\u003ch3\u003eSignal Output and Power Requirements\u003c\/h3\u003e\n\u003cp\u003eThe sensor operates as an ICP piezoelectric voltage-output device requiring 18-28 VDC excitation and 2-20 mA constant current. This two-wire constant-current excitation architecture supplies power and carries the conditioned vibration signal back to compatible monitoring channels.\u003c\/p\u003e\n\u003cp\u003eWith a +\/-50 g measurement range and a 5,000 g peak shock limit, the A0760GP accommodates standard industrial vibration levels while tolerating transient mechanical shocks. Its 0.5-10,000 Hz frequency response covers low-frequency unbalance and alignment faults up to higher-frequency bearing and mechanical fault harmonics.\u003c\/p\u003e\n\u003ch3\u003eMechanical Construction and Operating Conditions\u003c\/h3\u003e\n\u003cp\u003eA hermetically sealed stainless steel housing protects internal sensing elements from moisture and contaminants. The unit uses a 2-pin MIL-C-5015 electrical connector and a 1\/4-28 UNF-2B mounting thread for mechanical attachment.\u003c\/p\u003e\n\u003cp\u003eThe rated operating temperature spans -54 deg C to +121 deg C. Source specifications also list a weight of 1 kg, which is unusually heavy for a standard industrial accelerometer and should be verified against factory documentation before structural or stud-mount planning.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eA0760GP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eEmerson\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eEmerson \/ EPRO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eIndustrial Accelerometer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eAMS Machinery Health\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor Type\u003c\/td\u003e\n\u003ctd\u003eICP Piezoelectric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Type\u003c\/td\u003e\n\u003ctd\u003eVoltage Output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensitivity\u003c\/td\u003e\n\u003ctd\u003e100 mV\/g +\/-5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Range\u003c\/td\u003e\n\u003ctd\u003e+\/-50 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency Range\u003c\/td\u003e\n\u003ctd\u003e0.5-10,000 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExcitation Voltage\u003c\/td\u003e\n\u003ctd\u003e18-28 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConstant Current\u003c\/td\u003e\n\u003ctd\u003e2-20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShock Limit\u003c\/td\u003e\n\u003ctd\u003e5,000 g peak\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-54 deg C to +121 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector\u003c\/td\u003e\n\u003ctd\u003e2-pin MIL-C-5015\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Thread\u003c\/td\u003e\n\u003ctd\u003e1\/4-28 UNF-2B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHousing Material\u003c\/td\u003e\n\u003ctd\u003eStainless Steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSealing\u003c\/td\u003e\n\u003ctd\u003eHermetically Sealed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What excitation power does the A0760GP require? A: It requires 18-28 VDC excitation voltage and 2-20 mA constant current for its ICP piezoelectric voltage output.\u003c\/p\u003e\n\u003cp\u003eQ: What vibration and shock limits apply to the A0760GP? A: Its measurement range is +\/-50 g with a frequency range of 0.5-10,000 Hz, and its shock limit is up to 5,000 g peak.\u003c\/p\u003e\n\u003cp\u003eQ: Can the A0760GP be used in hazardous locations? A: The provided source material does not confirm hazardous-location certifications; hermetic sealing and stainless steel construction support rugged industrial environments, but explosive-atmosphere suitability requires verified hazardous-area ratings for the specific unit.\u003c\/p\u003e","brand":"Emerson","offers":[{"title":"Default Title","offer_id":51475094470968,"sku":"A0760GP","price":200.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/A0760GP.jpg?v=1764916654","url":"https:\/\/www.automodulexpert.com\/products\/emerson-a0760gp-icp-industrial-accelerometer-vibration-sensor","provider":"AutoModuleXpert Ltd.","version":"1.0","type":"link"}