Emerson PR6424/000-100 Eddy Current Sensor
The Emerson PR6424/000-100 is a non-contact 16 mm eddy current displacement sensor designed to measure shaft vibration, radial and axial displacement, position, and eccentricity on rotating machinery when paired with a compatible signal converter such as CON021. Specifications note a 4.0 mm standard measuring range (+- 2.0 mm static range), 4 V/mm sensitivity, and a minimum target shaft diameter of approximately 80 mm. Probe operating temperature is listed as -35 deg C to +150 deg C in Emerson PR6424 series documentation, with -35 deg C to +120 deg C in the system table and -35 deg C to +150 deg C in the probe FAQ.
Sensing Operation and Measurement Parameters
Non-contact eddy current probes generate an electromagnetic field at the sensing tip and detect changes in gap distance relative to a conductive target surface without mechanical contact. With a compatible converter such as CON021, the sensor supports vibration, axial thrust/position, and eccentricity measurements on ferromagnetic steel shafts (typically 42CrMo4).
- Range and Sensitivity: Listed with a 4.0 mm standard measuring range (+- 2.0 mm static range), 4 V/mm sensitivity, and linearity error less than or equal to +- 1.5%.
- Gap and Target Geometry: Specified with an approximately 2.7 mm initial measuring gap and a minimum shaft diameter of approximately 80 mm on ferromagnetic steel targets such as 42CrMo4.
- Converter Bandwidth: When used with a CON021 converter, the system specification table lists a 0–20 kHz (-3 dB) frequency response and less than 15 us rise time.
Converter Pairing and Thermal Notes
When paired with a CON021 signal converter, the system specification table lists converter supply voltages of -23 to -32 VDC or -21 to -32 VDC (depending on output configuration), output ranges of -4 to -20 VDC or -2 to -18 VDC, and IP20 converter protection (while CON021 overview text also mentions 4-20 mA or 0-10 V DC outputs and IP65 protection). Probe operating temperature is cited as -35 deg C to +120 deg C in the CON021 system table and -35 deg C to +150 deg C in the probe FAQ and Emerson PR6424 documentation.
- Converter Configuration: Confirm output range (-4 to -20 VDC or -2 to -18 VDC) and supply voltage (-23 to -32 VDC or -21 to -32 VDC) for the CON021 channel before wiring.
- Temperature and Suffix Check: Verify exact probe temperature limits (-35 deg C to +120 deg C vs. -35 deg C to +150 deg C) and /000-100 cable/mechanical suffix details against your order record and nameplate.
Technical Specifications
| Parameter | Specification |
|---|---|
| Model | PR6424/000-100 |
| Brand | Emerson (EPRO) |
| Product Type | Eddy Current Sensor |
| Measurement Principle | Non-contact eddy-current |
| Probe Tip Diameter | 16 mm |
| Standard Measuring Range | 4.0 mm |
| Static Measuring Range | +- 2.0 mm |
| Sensitivity | 4 V/mm |
| Linearity Error | Less than or equal to +- 1.5% |
| Initial Measuring Gap | 2.7 mm |
| Minimum Shaft Diameter | 80 mm |
| Target Material | Ferromagnetic steel, typically 42CrMo4 |
| Converter Frequency Response | 0–20 kHz (-3 dB) (with CON021) |
| Converter Rise Time | Less than 15 us (with CON021) |
| Converter Supply Voltage | -23 to -32 VDC or -21 to -32 VDC, depending on output configuration (with CON021) |
| Converter Output | -4 to -20 VDC or -2 to -18 VDC (with CON021) |
| Converter Protection | IP20 (with CON021) |
| Probe Operating Temperature | -35 deg C to +120 deg C (system table) / -35 deg C to +150 deg C (probe FAQ) |
Frequently Asked Questions
Q: What measuring range, sensitivity, and linearity apply to the PR6424/000-100? A: Specifications list a 4.0 mm standard measuring range (+- 2.0 mm static range), 4 V/mm sensitivity, linearity error less than or equal to +- 1.5%, and an initial measuring gap of approximately 2.7 mm. Confirm target shaft material and channel scaling during installation and calibration.
Q: What minimum shaft diameter and target material are specified for this 16 mm probe? A: The system specification table lists a minimum shaft diameter of approximately 80 mm with ferromagnetic steel targets such as 42CrMo4. Verify mechanical mounting clearance and target geometry before installation.
Q: Why do the notes show different temperature and converter output details? A: Probe operating temperature is listed as -35 deg C to +120 deg C in the CON021 system table and -35 deg C to +150 deg C in the probe FAQ and PR6424 documentation, while converter outputs are listed as -4 to -20 VDC or -2 to -18 VDC (and 4-20 mA or 0-10 V DC in the CON021 overview). Confirm the exact part configuration and operating conditions before ordering.
| Quick Quotes | Receive price & availability FAST from our dedicated customer service team. |
|---|---|
| Delivery | Expedited, Freight, And International Shipping Available. |
| Condition | 100% New with Original Package |
| Payment | We accept American Express, Discover, MasterCard, PayPal, and Visa. Our site is secured by RapidSSL. |
| Shipping Port | ShangHai, Xiamen |
| Warranty | 12 Months |
| Q: Is Our Pricing Competitive? |
| A: Yes, we collaborate with over 50 countries worldwide. As a top supplier in China, we offer significant discounts based on market trends. |
| Q: What Is the Warranty Period? |
| A: All our new and original products come with a standard one-year warranty. |
| Q: What Payment Methods Do We Accept? |
| A: We require 100% T/T (Telegraphic Transfer) payment before shipping. For items with a lead time, a 30% deposit is needed upfront, and the remaining 70% is due before shipping. If you have a representative in China, you can arrange an RMB transfer through them. |
| Q: What Shipping Methods Do We Use? |
| A: We primarily use FedEx, DHL, UPS, and BRE for shipping. If you have an account with any of these carriers, you can handle shipping directly. We also offer free shipping to China-based freight forwarders. |
| Q: What Is Our Delivery Time? |
| A: Delivery usually takes 1-3 days after receiving the initial payment. For items with a lead time, shipping will occur according to the specified schedule. |
| Q: How Do We Package the Goods? |
| A: We ensure safe packaging with multiple layers of protection. Products are first placed in their original boxes and sealed with labels. A layer of bubble wrap is then added for collision protection during transit. Finally, the items are packed securely in durable boxes. |
| Q: How Can Customers Contact Us and Request a Quote? |
| A: You can reach out to us via email, WhatsApp, WeChat, Skype, or your preferred communication platform. Contact us with your needs, and we'll provide a prompt, customized quote. |