{"product_id":"emerson-pr6424-000-100-16mm-eddy-current-sensor","title":"Emerson PR6424\/000-100 16mm Eddy Current Sensor","description":"\u003ch2\u003eEmerson PR6424\/000-100 Eddy Current Sensor\u003c\/h2\u003e\n\u003cp\u003eThe Emerson \u003cstrong\u003ePR6424\/000-100\u003c\/strong\u003e is a non-contact 16 mm eddy current displacement sensor designed to measure shaft vibration, radial and axial displacement, position, and eccentricity on rotating machinery when paired with a compatible signal converter such as CON021. Specifications note a 4.0 mm standard measuring range (+- 2.0 mm static range), 4 V\/mm sensitivity, and a minimum target shaft diameter of approximately 80 mm. Probe operating temperature is listed as -35 deg C to +150 deg C in Emerson PR6424 series documentation, with -35 deg C to +120 deg C in the system table and -35 deg C to +150 deg C in the probe FAQ.\u003c\/p\u003e\n\u003ch3\u003eSensing Operation and Measurement Parameters\u003c\/h3\u003e\n\u003cp\u003eNon-contact eddy current probes generate an electromagnetic field at the sensing tip and detect changes in gap distance relative to a conductive target surface without mechanical contact. With a compatible converter such as CON021, the sensor supports vibration, axial thrust\/position, and eccentricity measurements on ferromagnetic steel shafts (typically 42CrMo4).\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRange and Sensitivity:\u003c\/strong\u003e Listed with a 4.0 mm standard measuring range (+- 2.0 mm static range), 4 V\/mm sensitivity, and linearity error less than or equal to +- 1.5%.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGap and Target Geometry:\u003c\/strong\u003e Specified with an approximately 2.7 mm initial measuring gap and a minimum shaft diameter of approximately 80 mm on ferromagnetic steel targets such as 42CrMo4.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConverter Bandwidth:\u003c\/strong\u003e When used with a CON021 converter, the system specification table lists a 0–20 kHz (-3 dB) frequency response and less than 15 us rise time.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eConverter Pairing and Thermal Notes\u003c\/h3\u003e\n\u003cp\u003eWhen paired with a CON021 signal converter, the system specification table lists converter supply voltages of -23 to -32 VDC or -21 to -32 VDC (depending on output configuration), output ranges of -4 to -20 VDC or -2 to -18 VDC, and IP20 converter protection (while CON021 overview text also mentions 4-20 mA or 0-10 V DC outputs and IP65 protection). Probe operating temperature is cited as -35 deg C to +120 deg C in the CON021 system table and -35 deg C to +150 deg C in the probe FAQ and Emerson PR6424 documentation.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eConverter Configuration:\u003c\/strong\u003e Confirm output range (-4 to -20 VDC or -2 to -18 VDC) and supply voltage (-23 to -32 VDC or -21 to -32 VDC) for the CON021 channel before wiring.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature and Suffix Check:\u003c\/strong\u003e Verify exact probe temperature limits (-35 deg C to +120 deg C vs. -35 deg C to +150 deg C) and \/000-100 cable\/mechanical suffix details against your order record and nameplate.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003ePR6424\/000-100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eEmerson (EPRO)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eEddy Current Sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Principle\u003c\/td\u003e\n\u003ctd\u003eNon-contact eddy-current\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe Tip Diameter\u003c\/td\u003e\n\u003ctd\u003e16 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard Measuring Range\u003c\/td\u003e\n\u003ctd\u003e4.0 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStatic Measuring Range\u003c\/td\u003e\n\u003ctd\u003e+- 2.0 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensitivity\u003c\/td\u003e\n\u003ctd\u003e4 V\/mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLinearity Error\u003c\/td\u003e\n\u003ctd\u003eLess than or equal to +- 1.5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInitial Measuring Gap\u003c\/td\u003e\n\u003ctd\u003e2.7 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Shaft Diameter\u003c\/td\u003e\n\u003ctd\u003e80 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTarget Material\u003c\/td\u003e\n\u003ctd\u003eFerromagnetic steel, typically 42CrMo4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConverter Frequency Response\u003c\/td\u003e\n\u003ctd\u003e0–20 kHz (-3 dB) (with CON021)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConverter Rise Time\u003c\/td\u003e\n\u003ctd\u003eLess than 15 us (with CON021)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConverter Supply Voltage\u003c\/td\u003e\n\u003ctd\u003e-23 to -32 VDC or -21 to -32 VDC, depending on output configuration (with CON021)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConverter Output\u003c\/td\u003e\n\u003ctd\u003e-4 to -20 VDC or -2 to -18 VDC (with CON021)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConverter Protection\u003c\/td\u003e\n\u003ctd\u003eIP20 (with CON021)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe Operating Temperature\u003c\/td\u003e\n\u003ctd\u003e-35 deg C to +120 deg C (system table) \/ -35 deg C to +150 deg C (probe FAQ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003cp\u003eFrequently Asked Questions\u003c\/p\u003e\n\u003cp\u003eQ: What measuring range, sensitivity, and linearity apply to the PR6424\/000-100? A: Specifications list a 4.0 mm standard measuring range (+- 2.0 mm static range), 4 V\/mm sensitivity, linearity error less than or equal to +- 1.5%, and an initial measuring gap of approximately 2.7 mm. Confirm target shaft material and channel scaling during installation and calibration.\u003c\/p\u003e\n\u003cp\u003eQ: What minimum shaft diameter and target material are specified for this 16 mm probe? A: The system specification table lists a minimum shaft diameter of approximately 80 mm with ferromagnetic steel targets such as 42CrMo4. Verify mechanical mounting clearance and target geometry before installation.\u003c\/p\u003e\n\u003cp\u003eQ: Why do the notes show different temperature and converter output details? A: Probe operating temperature is listed as -35 deg C to +120 deg C in the CON021 system table and -35 deg C to +150 deg C in the probe FAQ and PR6424 documentation, while converter outputs are listed as -4 to -20 VDC or -2 to -18 VDC (and 4-20 mA or 0-10 V DC in the CON021 overview). Confirm the exact part configuration and operating conditions before ordering.\u003c\/p\u003e","brand":"EPRO","offers":[{"title":"Default Title","offer_id":51483817115960,"sku":"CON021+PR6424\/000-100","price":256.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/CON021_PR6423010-000.jpg?v=1765157823","url":"https:\/\/www.automodulexpert.com\/products\/emerson-pr6424-000-100-16mm-eddy-current-sensor","provider":"AutoModuleXpert Ltd.","version":"1.0","type":"link"}