{"product_id":"esb-bus-cable-yokogawa-ycb301-c300","title":"ESB Bus Cable YOKOGAWA YCB301-C300","description":"\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYCB301-C300\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ehigh-performance ESB Bus interconnect cable\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edesigned for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYokogawa CENTUM VP\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCS 3000 systems\u003c\/strong\u003e. It provides a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003edeterministic high-speed data link\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ebetween Field Control Units (FCUs) and ANB node units.\u003c\/p\u003e\n\u003cp\u003eThe YCB301-C300 (Model:\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYCB301\u003c\/strong\u003e, Suffix:\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e-C300\u003c\/strong\u003e) features\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e36-pin high-density connectors\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003erobust shielding\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto ensure signal integrity in industrial control environments.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Function\u003c\/td\u003e\n\u003ctd\u003eESB Bus inter-node \/ FCU-to-node connectivity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Interface\u003c\/td\u003e\n\u003ctd\u003eDual 36-pin high-density industrial connectors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhysical Length\u003c\/td\u003e\n\u003ctd\u003e3 meters \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Architecture\u003c\/td\u003e\n\u003ctd\u003eMulti-core twisted pair with localized shielding\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eImpedance Matching\u003c\/td\u003e\n\u003ctd\u003eFactory-calibrated to prevent signal reflection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMechanical Durability\u003c\/td\u003e\n\u003ctd\u003eHeavy-duty jacket, abrasion and chemical resistant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSecurity\u003c\/td\u003e\n\u003ctd\u003eCaptive screw-locks to prevent accidental disconnection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch2\u003eSystem Implementation and Safety\u003c\/h2\u003e\n\u003cp\u003eThe YCB301-C300 is optimized for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eintra-cabinet or adjacent cabinet connections\u003c\/strong\u003e:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eProvides sufficient slack for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003estructured cable management\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEnsures\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003elow propagation delay\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ehigh-integrity shielding\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePrevents\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eelectromagnetic interference (EMI)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efrom nearby high-power equipment\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSuitable for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eredundant ESB bus configurations\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eusing two cables (Bus 1 \u0026amp; Bus 2)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eCan this cable be used for Vnet\/IP connections?\u003c\/strong\u003e\u003cbr\u003eNo. The YCB301-C300 is\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003estrictly for ESB Bus connections\u003c\/strong\u003e. Vnet\/IP requires different interfaces such as the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eVI702 card\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand Ethernet or fiber cabling.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the cable support redundant configurations?\u003c\/strong\u003e\u003cbr\u003eYes. Redundant ESB systems use\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003etwo cables\u003c\/strong\u003e—one for each bus segment—to ensure\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003econtinuous communication\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eif a single cable fails.\u003c\/p\u003e","brand":"YOKOGAWA","offers":[{"title":"Default Title","offer_id":51762101518648,"sku":"YCB301-C300","price":188.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/ESB_YCB301-C100.jpg?v=1770603239","url":"https:\/\/www.automodulexpert.com\/products\/esb-bus-cable-yokogawa-ycb301-c300","provider":"AutoModuleXpert Ltd.","version":"1.0","type":"link"}