{"product_id":"esb-bus-node-unit-yokogawa-anb10n-410-cu2t-ndel","title":"ESB Bus Node Unit Yokogawa ANB10N-410\/CU2T\/NDEL","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eANB10N-410\/CU2T\/NDEL\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a specialized expansion interface designed for the Yokogawa\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCENTUM VP\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edistributed control system. As a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eNon-Redundant ESB Bus Node Unit\u003c\/strong\u003e, it provides a cost-effective solution for I\/O expansion in applications where\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003esingle-bus communication\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis sufficient and full communication redundancy is not required.\u003c\/p\u003e\n\u003cp\u003eThis unit enables connection between multiple I\/O modules and the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eField Control Unit (FCU)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003evia the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eExtended Serial Backplane (ESB) bus\u003c\/strong\u003e, ensuring deterministic data acquisition within the control system.\u003c\/p\u003e\n\u003cp\u003eDespite being a non-redundant communication node, it is equipped with a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003edual-redundant power supply (100–120 V AC)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto enhance hardware availability and operational stability.\u003c\/p\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCU2T connector\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eincludes an\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eintegrated terminator\u003c\/strong\u003e, making this unit suitable as the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003efinal node in an ESB bus chain\u003c\/strong\u003e. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e\/NDEL license\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis pre-installed, authorizing the node for system integration within CENTUM VP.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePrimary Function:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eESB bus expansion node (non-redundant communication)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower Supply:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDual-redundant (100–120 V AC)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConnector Type:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCU2T (with integrated termination)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBus Role:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTerminal node (end-of-chain)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSoftware License:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\/NDEL included\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eApplication Focus:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eNon-critical, cost-efficient I\/O expansion\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Identification\u003c\/td\u003e\n\u003ctd\u003eANB10N-410\/CU2T\/NDEL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Role\u003c\/td\u003e\n\u003ctd\u003eNon-redundant ESB bus node unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Redundancy\u003c\/td\u003e\n\u003ctd\u003eSingle ESB bus (non-redundant)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply Redundancy\u003c\/td\u003e\n\u003ctd\u003eDual-redundant (parallel configuration)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e100–120 V AC (50\/60 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e200 VA \/ 120 W (depends on load)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Interface\u003c\/td\u003e\n\u003ctd\u003eCU2T (integrated terminator)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBus Termination\u003c\/td\u003e\n\u003ctd\u003eIncludes 2 × S9564FA terminators\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSoftware Licensing\u003c\/td\u003e\n\u003ctd\u003e\/NDEL (node expansion license included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eI\/O Module Capacity\u003c\/td\u003e\n\u003ctd\u003eUp to 8 I\/O modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Standard\u003c\/td\u003e\n\u003ctd\u003e19-inch rack mount (8U)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExplosion Protection\u003c\/td\u003e\n\u003ctd\u003eBasic type (non-Ex)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e 10 kg \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eOperational Applications\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eANB10N-410\/CU2T\/NDEL\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis typically used in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eutility systems, water treatment plants, and non-critical auxiliary control loops\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eIt is especially suitable for:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eNon-critical I\/O expansion\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCost-sensitive industrial control architectures\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTerminal nodes in ESB bus chains\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eBy combining\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003edual-redundant power\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ewith\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003enon-redundant communication\u003c\/strong\u003e, it offers a balanced solution for applications where\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eavailability is important but full redundancy is not required\u003c\/strong\u003e.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical FAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the difference between the ANB10N and ANB10D models?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eANB10N\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003euses a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003enon-redundant ESB bus communication structure\u003c\/strong\u003e, while the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eANB10D\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esupports\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003edual-redundant communication\u003c\/strong\u003e, making it suitable for mission-critical applications requiring higher fault tolerance.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Why is the CU2T connector required for this node?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCU2T connector includes an integrated terminator\u003c\/strong\u003e, which is required for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003efinal node in an ESB bus chain\u003c\/strong\u003e. Proper termination prevents signal reflections and ensures stable communication across the bus.\u003c\/p\u003e","brand":"YOKOGAWA","offers":[{"title":"Default Title","offer_id":51913671147832,"sku":"ANB10N-410\/CU2T\/NDEL","price":188.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/ANB10D-427CU2N2.jpg?v=1773884188","url":"https:\/\/www.automodulexpert.com\/products\/esb-bus-node-unit-yokogawa-anb10n-410-cu2t-ndel","provider":"AutoModuleXpert Ltd.","version":"1.0","type":"link"}