{"product_id":"esb-bus-node-unit-yokogawa-centum-cs-3000-anr11d-410-ndel","title":"ESB Bus Node Unit Yokogawa CENTUM CS 3000 ANR11D-410\/NDEL","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eANR11D-410\/NDEL\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-performance ESB Bus Node Unit designed for integration within the Yokogawa CENTUM CS 3000 and Yokogawa CENTUM VP architectures.\u003c\/p\u003e\n\u003cp\u003eIt operates as a communication bridge between the Field Control Station (FCS) and distributed I\/O modules, enabling deterministic, high-speed data exchange over the ESB Bus. The architecture ensures reliable analog and digital signal processing with strong immunity to electrical noise—critical for mission-critical industrial environments.\u003c\/p\u003e\n\u003cp\u003eThe ANR11D-410\/NDEL integrates:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e8 isolated analog input channels\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e8 isolated analog output channels\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e16-bit high-resolution A\/D and D\/A converters\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eG3-compliant environmental ruggedization\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThis combination delivers high measurement precision and long-term durability in demanding process control applications.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Number\u003c\/td\u003e\n\u003ctd\u003eANR11D-410\/NDEL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBus Interface\u003c\/td\u003e\n\u003ctd\u003eESB Bus (CENTUM system integration)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Input Channels\u003c\/td\u003e\n\u003ctd\u003e8 isolated channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e24 V DC (19.2 V to 28.8 V allowable range)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Power Consumption\u003c\/td\u003e\n\u003ctd\u003e15 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-10 °C to +60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhysical Dimensions\u003c\/td\u003e\n\u003ctd\u003e180 mm × 160 mm × 40 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMass\u003c\/td\u003e\n\u003ctd\u003e1.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eApplication and Systems Integration\u003c\/h3\u003e\n\u003cp\u003eThe ANR11D-410\/NDEL is widely deployed in distributed control systems across:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eOil and gas facilities\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eChemical processing plants\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePower generation stations\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eBy functioning as a localized ESB node, it reduces field wiring distances and improves installation efficiency while maintaining synchronized communication with the central controller. Its high-resolution conversion and isolation architecture make it suitable for precision control loops involving temperature, pressure, and flow measurements.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the ANR11D-410\/NDEL handle signal interference?\u003c\/strong\u003e\u003cbr\u003eThe module employs galvanic isolation between field circuits and the internal system bus, combined with advanced filtering techniques to suppress electromagnetic interference (EMI) and common-mode noise.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this module be used in redundant configurations?\u003c\/strong\u003e\u003cbr\u003eYes. Within the CENTUM CS 3000 and CENTUM VP frameworks, the ANR11D-410\/NDEL supports duplexed ESB bus configurations, ensuring continuous operation in the event of a single communication path failure.\u003c\/p\u003e","brand":"YOKOGAWA","offers":[{"title":"Default Title","offer_id":51833476612408,"sku":"ANR11D-410 NDEL","price":188.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/ANR11D-410_NDEL1.jpg?v=1772070832","url":"https:\/\/www.automodulexpert.com\/products\/esb-bus-node-unit-yokogawa-centum-cs-3000-anr11d-410-ndel","provider":"AutoModuleXpert Ltd.","version":"1.0","type":"link"}