{"product_id":"f3xc08-0c-yokogawa-digital-input-module","title":"F3XC08-0C Yokogawa Digital Input Module","description":"\u003ch2\u003e\u003cstrong\u003eProduct Description\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eF3XC08-0C\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ehigh-precision discrete input module\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYokogawa FA-M3 \"Range-Free\" multi-controller series\u003c\/strong\u003e, designed to interface with\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003edry (no-voltage) contacts\u003c\/strong\u003e. It is ideal for monitoring mechanical switches, relay contacts, or sensors that do not supply their own electrical signal.\u003c\/p\u003e\n\u003cp\u003eThis module features\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eper-channel transformer isolation\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ewith separate commons for each input, preventing ground loops and minimizing electrical noise. Engineers can configure the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eresponse time\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efrom\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e0 µs to 16 ms\u003c\/strong\u003e, enabling a balance between\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ehigh-speed detection\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003enoise-filtered signal acquisition\u003c\/strong\u003e.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003e\u003cstrong\u003eItem\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Number\u003c\/td\u003e\n\u003ctd\u003eF3XC08-0C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eDry Contact \/ No-Voltage Discrete Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Capacity\u003c\/td\u003e\n\u003ctd\u003e8 independent channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommon Configuration\u003c\/td\u003e\n\u003ctd\u003eSeparate common terminal per channel (fully isolated)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Technology\u003c\/td\u003e\n\u003ctd\u003eTransformer-based isolation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact Requirements\u003c\/td\u003e\n\u003ctd\u003e≥5 V DC, ≥20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical Thresholds\u003c\/td\u003e\n\u003ctd\u003eON Resistance ≤200 Ω; OFF Resistance ≥100 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time \/ Filter\u003c\/td\u003e\n\u003ctd\u003e5 selectable stages: 0 µs, 62.5 µs, 250 µs, 1 ms, 16 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eMax 500 mA (internal 5 V DC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhysical Dimensions\u003c\/td\u003e\n\u003ctd\u003e28.9 mm (W) × 100 mm (H) × 83.2 mm (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnit Weight\u003c\/td\u003e\n\u003ctd\u003e0.5kg\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePlatform Compatibility\u003c\/td\u003e\n\u003ctd\u003eStandard I\/O slots for Yokogawa FA-M3 series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch2\u003e\u003cstrong\u003eApplication Scenarios\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Speed Machine Control\u003c\/strong\u003e: Capturing instantaneous signals from fast mechanical limit switches using the 0 µs response setting.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eElectrically Noisy Environments\u003c\/strong\u003e: Applying the 16 ms filter to monitor pushbuttons or relay contacts in areas with high EMI.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIsolated Signal Monitoring\u003c\/strong\u003e: Safely interfacing with contacts from independent external systems where ground potential differences exist.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"YOKOGAWA","offers":[{"title":"Default Title","offer_id":51718818693432,"sku":"F3XC08-0C","price":188.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/F3XC08-0C.jpg?v=1770349681","url":"https:\/\/www.automodulexpert.com\/products\/f3xc08-0c-yokogawa-digital-input-module","provider":"AutoModuleXpert Ltd.","version":"1.0","type":"link"}