{"product_id":"fail-safe-digital-output-fta-honeywell-fta-t-08-fsc","title":"Fail-Safe Digital Output FTA | Honeywell FTA-T-08 FSC","description":"\u003ch2\u003eHoneywell FTA-T-08 FSC Fail-Safe Digital Output FTA\u003c\/h2\u003e\n\u003cp\u003eConfigured for fail-safe digital signal termination in Honeywell Fail Safe Control (FSC) safety platforms, the \u003cstrong\u003eHoneywell FTA-T-08\u003c\/strong\u003e (\u003cstrong\u003eFTA-T-08\u003c\/strong\u003e Fail-Safe Digital Output FTA) provides direct physical\/electrical execution for four independent relay channels.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eFTA-T-08\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eNetherlands\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.26 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e146 x 70 x 68 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eNominal 24 VDC (50 mA per channel at 24 VDC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Configuration\u003c\/td\u003e\n\u003ctd\u003e4 fail-safe channels (Dual series relays per channel)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eField Contact Type\u003c\/td\u003e\n\u003ctd\u003eFused normally open (NO) contact (3.15 AT slow-acting)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Switching Voltage\u003c\/td\u003e\n\u003ctd\u003e250 VAC \/ 150 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Continuous Current\u003c\/td\u003e\n\u003ctd\u003e3.15 A per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eField Wiring\u003c\/td\u003e\n\u003ctd\u003eScrew terminals (AWG 14 max)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Format\u003c\/td\u003e\n\u003ctd\u003eDIN rail (TS32 \/ TS35 x 7.5)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eChannel-to-Channel Isolation and Fail-Safe Execution\u003c\/h3\u003e\n\u003cp\u003eIn high-integrity safety applications, discrete output nodes require strict electrical isolation and guaranteed de-energization under fault conditions. The \u003cstrong\u003eHoneywell FTA-T-08\u003c\/strong\u003e uses two series-connected relays per channel sourced from diverse manufacturers to eliminate common-cause hardware failures. Channel-to-channel isolation prevents cross-talk and stray loop currents from interfering with 4-20 mA HART signal lines or adjacent digital outputs, while integrated status LEDs provide local diagnostic feedback. When a trip signal drops input drive voltage below the 19 VDC cut-in threshold, both series relay contacts drop out immediately to enforce a true fail-safe open state.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How does the dual-relay configuration enforce fail-safe performance during a contact welding event?\u003c\/p\u003e\n\u003cp\u003eA: By placing two independent relays in series for each output path, the channel maintains the ability to open the load circuit even if one relay contact welds closed due to an overcurrent surge.\u003c\/p\u003e\n\u003cp\u003eQ: What are the primary replacement guidelines for the channel fuse?\u003c\/p\u003e\n\u003cp\u003eA: Replace blown fuses exclusively with 3.15 AT slow-acting fuses rated for the full field load voltage. Verify that external field loads remain within the maximum 800 VA \/ 150 W switching limits before re-energizing the loop.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eSnap the module onto standard TS32 or TS35 x 7.5 DIN rail sections inside the marshalling cabinet, ensuring the mounting clip latches securely to maintain chassis grounding integrity.\u003c\/p\u003e\n\u003cp\u003eConnect the System Interconnection Cable (SIC-C-02) firmly into the onboard T10 interface connector. Route field wiring away from high-voltage AC lines through separate wire ducts to prevent inductive noise pickup. Tighten field screw terminals carefully to ensure low-resistance wiring connections without over-torque damage. Before servicing or changing fuses, isolate external power supplies to prevent electrical shock or unintended trip activations.\u003c\/p\u003e","brand":"HONEYWELL","offers":[{"title":"Default Title","offer_id":51284166869304,"sku":"FTA-T-08","price":250.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/FTA-T-08.jpg?v=1761547924","url":"https:\/\/www.automodulexpert.com\/products\/fail-safe-digital-output-fta-honeywell-fta-t-08-fsc","provider":"AutoModuleXpert Ltd.","version":"1.0","type":"link"}