{"product_id":"fc-tsro-0824-honeywell-safety-manager-relay-output-module","title":"FC-TSRO-0824 Honeywell Safety Manager Relay Output Module","description":"\u003ch2\u003eHoneywell FC-TSRO-0824 Digital Output Relay FTA\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell FC-TSRO-0824\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eFC-TSRO-0824\u003c\/strong\u003e Digital Output Relay Field Termination Assembly, operates as a dedicated hardware component for switching high-capacity field loads within Honeywell Safety Manager platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eFC-TSRO-0824\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eStandard manufacturing origin\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.45 kg (1.0 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e300 x 70 x 60 mm (11.81 x 2.76 x 2.36 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-5 deg C to +60 deg C (23 deg F to 140 deg F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eTypical input current 40 mA at 24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eHoneywell Safety Manager \/ FSC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Count\u003c\/td\u003e\n\u003ctd\u003e8 relay digital output channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Input Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC (19.2 VDC pick-up voltage)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Switched Voltage\u003c\/td\u003e\n\u003ctd\u003e250 VAC \/ 250 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Switched Current\u003c\/td\u003e\n\u003ctd\u003e5 A (fused with 5 A slow-acting 5 x 20 mm fuse)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Rating\u003c\/td\u003e\n\u003ctd\u003eSIL 3 capable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e4-20 mA HART Loop Protocol \u0026amp; Channel Isolation\u003c\/h3\u003e\n\u003cp\u003eThe module architecture incorporates physical contact separation to provide complete channel-to-channel isolation between field actuator loops and internal controller backplane logic. Conformal coating shields onboard switching components from industrial atmospheric contaminants and moisture. Although designed primarily for discrete relay switching, the module coexists within Safety Manager cabinets alongside standard 4-20 mA HART loop protocol instruments to facilitate integrated DCS field execution.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What is the maximum switching capacity per output relay channel on the FC-TSRO-0824?\u003c\/p\u003e\n\u003cp\u003eA: Each of the 8 channels switches up to 5 A at 250 VAC or 250 VDC, handling a maximum switched load of 1250 VA or 150 W.\u003c\/p\u003e\n\u003cp\u003eQ: What type of fuse protection is utilized on this field termination assembly?\u003c\/p\u003e\n\u003cp\u003eA: The board incorporates 5 A slow-acting fuses measuring 5 x 20 mm rated for 250 VAC and 150 VDC protection per channel.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eDisconnect all main supply power to the cabinet before commencing physical mounting or wiring tasks. Securely snap the assembly onto standard DIN EN TS32 or TS35 x 7.5 mounting rails using a minimum rail length of 301 mm. Strip field conductors to 7 mm (0.28 in) and connect wire gauges up to 2.5 mm² (AWG 14) directly into the screw terminals. Torque all terminal screws to 0.5 Nm (0.37 ft-lb) using a calibrated screwdriver to prevent loose physical connections under continuous operating vibration.\u003c\/p\u003e","brand":"HONEYWELL","offers":[{"title":"Default Title","offer_id":49525681815864,"sku":"FC-TSRO-0824","price":236.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/628._cca4e119-a342-46e9-a171-43095d21de71.jpg?v=1792138009","url":"https:\/\/www.automodulexpert.com\/products\/fc-tsro-0824-honeywell-safety-manager-relay-output-module","provider":"AutoModuleXpert Ltd.","version":"1.0","type":"link"}