{"product_id":"ge-ds200pccag1acb-power-connect-card","title":"GE DS200PCCAG1ACB Power Connect Card","description":"\u003cp\u003eThe \u003cstrong\u003eGE DS200PCCAG1ACB\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eDS200PCCAG1ACB\u003c\/strong\u003e Power Connect Card, operates as a dedicated hardware component for SCR power bridge interfacing within EX2000 drive systems.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eDS200PCCAG1ACB\u003c\/strong\u003e belongs to the EX2000 product line. The \"G1\" designation denotes the generation of the power interface circuitry, while the \"ACB\" suffix identifies the specific revision level of the assembly, which defines the physical mounting profile and signal routing compatibility with the drive's control circuitry.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eDS200PCCAG1ACB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGeneral Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.6kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003ctd\u003eGEI-100161\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunction\u003c\/td\u003e\n\u003ctd\u003eSCR bridge power interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane bus communication velocity and firmware compatibility\u003c\/h3\u003e\n\u003cp\u003eThe power connect card functions as the hardware link between the control logic and the high-power switching components of the EX2000 drive. To maintain system stability, the board facilitates deterministic signal transmission, ensuring that firing pulses reach the SCR power bridge within defined temporal windows. Firmware flash compatibility and bus communication velocity are monitored to prevent gate driver latency, ensuring the drive responds accurately to control signal requests while maintaining operational integrity across the internal communication backplane.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e\n\u003cp\u003eQ: What is the primary function of the DS200PCCAG1ACB in the EX2000 system?\u003c\/p\u003e\n\u003cp\u003eA: The board serves as the signal interface between the drive's low-voltage control circuitry and the high-voltage SCR power bridge. It ensures that command signals are correctly translated into firing pulses for the power semiconductors.\u003c\/p\u003e\n\u003cp\u003eQ: Is this module compatible with all EX2000 drives?\u003c\/p\u003e\n\u003cp\u003eA: Compatibility depends on the specific drive configuration and the revision level (G1ACB). Always consult the GEI-100161 manual for specific model verification before installation to ensure the pinout and electrical ratings match the system requirements.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eVerify that the drive system is locked out and tagged out (LOTO) and that the DC bus capacitors are fully discharged before accessing the interior of the drive cabinet.\u003c\/li\u003e\n\u003cli\u003eEnsure the cabinet environment is clean and maintained between 0 deg C and 60 deg C to prevent thermal degradation of the onboard components.\u003c\/li\u003e\n\u003cli\u003eAlign the card carefully with the internal interface connectors to avoid bending pins. Apply firm, even pressure until the card is fully seated.\u003c\/li\u003e\n\u003cli\u003eRoute all signal cables away from high-voltage power leads to prevent electromagnetic interference (EMI) or capacitive coupling that could induce erratic firing commands.\u003c\/li\u003e\n\u003cli\u003eInspect all electrical connections for mechanical security before re-energizing the control power.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"GE FANUC","offers":[{"title":"Default Title","offer_id":52609134887224,"sku":"DS200PCCAG1ACB","price":220.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/DS200PCCAG1ACB1.jpg?v=1783066770","url":"https:\/\/www.automodulexpert.com\/products\/ge-ds200pccag1acb-power-connect-card","provider":"AutoModuleXpert Ltd.","version":"1.0","type":"link"}