{"product_id":"ge-ds200qtbag1aba-rst-termination-board","title":"GE DS200QTBAG1ABA RST Termination Board","description":"\u003cp\u003eConfigured for high-density terminal interfacing in Mark V Speedtronic control system platforms, the \u003cstrong\u003eGE DS200QTBAG1ABA\u003c\/strong\u003e (\u003cstrong\u003eDS200QTBAG1ABA\u003c\/strong\u003e RST Termination Board) provides direct physical\/electrical execution. This hardware component serves as a primary termination interface for the RST core, facilitating the connection of field-side I\/O signals to the turbine control cabinet. The board is designed to route discrete and analog signals efficiently, ensuring that field feedback is accurately transmitted to the control processors for real-time turbine regulation and monitoring.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eDS200QTBAG1ABA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e 1 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard Mark V terminal board form factor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eIndustrial standard 0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eDependent on connected loop current\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eRST core signal termination\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eMark V Turbine Control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eIndustrial Control and I\/O Density Scaling\u003c\/h3\u003e\n\u003cp\u003eThe DS200QTBAG1ABA facilitates robust I\/O density scaling by offering a consolidated point for field-side wiring termination. The module supports backplane bus communication velocity by ensuring signal transition from field wiring to the controller remains within specified latency limits. By maintaining low-impedance pathways for analog and discrete inputs, the board minimizes signal noise, which is critical for the stability of turbine control loops. Firmware flash compatibility is managed at the system controller level, ensuring that the I\/O mapping remains synchronized with the turbine control logic.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can the DS200QTBAG1ABA be replaced while the turbine is running?\u003c\/p\u003e\n\u003cp\u003eA: No. Replacement of termination boards requires that the associated I\/O loops and control power be de-energized to prevent short-circuiting of field sensors or the induction of spurious signals into the control logic.\u003c\/p\u003e\n\u003cp\u003eQ: How should shields for shielded cabling be terminated on this board?\u003c\/p\u003e\n\u003cp\u003eA: Shields should be terminated at the designated common ground points on the cabinet's chassis or the board’s grounding bars to effectively shunt EMI\/RFI noise away from the signal conductors.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eConfirm that the system is isolated and follow LOTO procedures before beginning installation.\u003c\/li\u003e\n\u003cli\u003eVerify that the terminal board is correctly positioned on the standoffs to ensure adequate clearance from the cabinet backplane.\u003c\/li\u003e\n\u003cli\u003eSecure the board using the provided mounting hardware, ensuring all screws are tightened to establish a solid ground bond between the board and the chassis.\u003c\/li\u003e\n\u003cli\u003eTerminate all field-side conductors to the screw terminals; verify that torque settings are appropriate for the wire gauge to prevent loose connections.\u003c\/li\u003e\n\u003cli\u003eInspect the board for any loose jumpers or debris before closing the terminal cabinet.\u003c\/li\u003e\n\u003cli\u003eConduct a signal validation test from the field instrument to the operator HMI to confirm that inputs are correctly mapped and reporting valid process values.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"GE FANUC","offers":[{"title":"Default Title","offer_id":52614200787256,"sku":"DS200QTBAG1ABA","price":220.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/DS200QTBAG1ABA2.jpg?v=1783412322","url":"https:\/\/www.automodulexpert.com\/products\/ge-ds200qtbag1aba-rst-termination-board","provider":"AutoModuleXpert Ltd.","version":"1.0","type":"link"}