{"product_id":"ge-ds200tccbg8b-extended-analog-i-o-board","title":"GE DS200TCCBG8B Extended Analog I\/O Board","description":"\u003cp\u003eConfigured for precision signal acquisition in Mark V turbine control system platforms, the \u003cstrong\u003eGE DS200TCCBG8B\u003c\/strong\u003e (\u003cstrong\u003eDS200TCCBG8B\u003c\/strong\u003e Extended Analog I\/O Board) provides direct physical\/electrical execution. This hardware component serves as a specialized interface module within the TC2000 and Mark V architecture, responsible for processing complex analog inputs and distributing control signals. The board facilitates multi-channel data handling, ensuring that turbine parameters are monitored and regulated with the deterministic timing required for high-availability power generation.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eDS200TCCBG8B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.13 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard Mark V Eurocard form factor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eIndustrial standard 0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eDependent on active I\/O loop load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eExtended Analog I\/O Board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eMark V \/ TC2000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eIndustrial Control and I\/O Density Scaling\u003c\/h3\u003e\n\u003cp\u003eThe DS200TCCBG8B is engineered for high-density I\/O management, allowing for the consolidation of various analog instrumentation into the turbine control network. The module supports backplane bus communication velocity, ensuring that signal conversion and logic execution occur within the tight processing windows required by the turbine controller. The hardware supports I\/O density scaling through its multi-channel design, and firmware flash compatibility is maintained through the system-level interface, ensuring seamless integration with existing Mark V logic loops.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can this module be used in both Mark V and TC2000 environments?\u003c\/p\u003e\n\u003cp\u003eA: Yes. The board is designed for compatibility within the Mark V and TC2000 turbine control ecosystems; however, the specific system logic files must be configured to recognize the unique I\/O mapping of the G8B revision.\u003c\/p\u003e\n\u003cp\u003eQ: Is this board field-configurable for different analog signal ranges?\u003c\/p\u003e\n\u003cp\u003eA: Signal ranges are typically managed via system-level software configuration and onboard hardware jumpers. Refer to the specific site schematic to confirm the correct hardware jumper settings before applying power to the I\/O loops.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eEnsure the control cabinet is isolated from all power sources and verify zero-energy states using LOTO procedures.\u003c\/li\u003e\n\u003cli\u003eCarefully inspect the board's edge connectors for debris or oxidation before insertion into the backplane.\u003c\/li\u003e\n\u003cli\u003eSlide the module into the designated slot, ensuring the front-panel extraction\/insertion levers are fully engaged to guarantee proper grounding.\u003c\/li\u003e\n\u003cli\u003eSecure the board with the provided mounting hardware to prevent mechanical stress from turbine vibrations.\u003c\/li\u003e\n\u003cli\u003eTerminate all analog input and output wiring at the corresponding terminal blocks, ensuring that cable shields are bonded to the cabinet ground to minimize signal noise.\u003c\/li\u003e\n\u003cli\u003eVerify analog channel responsiveness through the turbine operator interface, performing a calibration check on each channel to ensure signal accuracy before initiating turbine operation.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"GE FANUC","offers":[{"title":"Default Title","offer_id":52614190006584,"sku":"DS200TCCBG8B","price":220.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/DS200TCCBG8BED.jpg?v=1782980885","url":"https:\/\/www.automodulexpert.com\/products\/ge-ds200tccbg8b-extended-analog-i-o-board","provider":"AutoModuleXpert Ltd.","version":"1.0","type":"link"}