{"product_id":"ge-fanuc-a02b-0236-b802-operator-interface-panel","title":"GE FANUC A02B-0236-B802 Operator Interface Panel","description":"\u003cp\u003eThe \u003cstrong\u003eGE FANUC A02B-0236-B802\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eA02B-0236-B802\u003c\/strong\u003e Color Operator Interface Panel, operates as a dedicated hardware component for machine control and process visualization within FANUC Series 160i-A CNC platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eA02B-0236-B802\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE FANUC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e6.0 lbs (2.72 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e10.4-inch display panel cutout dimensions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e24 VDC nominal (powered via CNC power supply unit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Type\u003c\/td\u003e\n\u003ctd\u003e10.4-inch color LCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Processor\u003c\/td\u003e\n\u003ctd\u003eIntegrated PC processor (MMX Pentium architecture)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpansion Capacity\u003c\/td\u003e\n\u003ctd\u003eMulti-slot backplane interface (up to 3 expansion slots)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrimary Application\u003c\/td\u003e\n\u003ctd\u003eHMI \/ MMI \/ OIT panel unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Type\u003c\/td\u003e\n\u003ctd\u003ePanel-mounted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus \u0026amp; Deterministic Communications\u003c\/h3\u003e\n\u003cp\u003eThe operator panel connects directly with the underlying FANUC 160i-A CNC rack assembly over high-speed internal system buses. Backplane bus communication velocity architecture allows real-time execution of embedded PC visualization processing alongside deterministic numeric control operations. Firmware flash compatibility across system PCBs ensures uninterrupted transfer of axis position coordinates, spindle diagnostics, and peripheral digital I\/O status data without introducing signal processing latency.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What are the primary backplane integration requirements when adding expansion PCBs to the A02B-0236-B802 unit?\u003c\/p\u003e\n\u003cp\u003eA: Optional expansion cards must be inserted into designated backplane slots with main system power completely disconnected. Ensure backplane connectors are clear of debris to maintain reliable high-speed bus pin seating.\u003c\/p\u003e\n\u003cp\u003eQ: How is thermal dissipation handled for the embedded PC processor in enclosed operator panels?\u003c\/p\u003e\n\u003cp\u003eA: Heat dissipation relies on internal conduction heat sinks and cabinet convection. Enclosure ambient temperatures must not exceed 55 deg C to prevent processor thermal throttling and display backlight degradation.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePanel Cutout and Sealing\u003c\/strong\u003e: Position the panel into the cabinet front door cut-out. Ensure the surrounding perimeter gasket is properly compressed to maintain cabinet ingress protection ratings against oil mist and coolant droplets.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCabinet Earthing\u003c\/strong\u003e: Bond the rear metallic chassis of the display panel directly to the machine ground bus using a braided copper grounding wire (minimum 4 mm sq cross-section) to suppress high-frequency electrical noise.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Separation and Routing\u003c\/strong\u003e: Route display signal lines, keyboard cables, and serial bus wires in dedicated wiring trunks separate from high-voltage motor power leads and AC contactor coils.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRetention and Locking\u003c\/strong\u003e: Tighten all perimeter mounting clamps evenly to avoid warping the display bezel. Verify that all option board retaining screws are fully secured prior to powering on the CNC system.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE FANUC","offers":[{"title":"Default Title","offer_id":52718594490680,"sku":"A02B-0236-B802","price":220.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/A02B-0236-B8022.jpg?v=1785315418","url":"https:\/\/www.automodulexpert.com\/products\/ge-fanuc-a02b-0236-b802-operator-interface-panel","provider":"AutoModuleXpert Ltd.","version":"1.0","type":"link"}