{"product_id":"ge-fanuc-analog-input-module-ic200alg263f","title":"GE Fanuc Analog Input Module IC200ALG263F","description":"\u003cp\u003eConfigured for high-resolution signal acquisition in VersaMax control networks, the \u003cstrong\u003eGE Fanuc IC200ALG263F\u003c\/strong\u003e (\u003cstrong\u003eIC200ALG263F\u003c\/strong\u003e Analog Input Module) provides direct physical\/electrical execution of 15-channel voltage monitoring.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eIC200ALG263F\u003c\/strong\u003e denotes a 15-channel analog input configuration. The \"F\" suffix signifies the specific hardware revision level, which incorporates the circuitry required for 15-bit A\/D conversion within the VersaMax I\/O module family.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC200ALG263F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eRefer to original shipping documentation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.45 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e100 mm x 80 mm x 20 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to 70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePowered via backplane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e15 single-ended\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Range\u003c\/td\u003e\n\u003ctd\u003e-10 VDC to 10 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e15-bit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUpdate Rate\u003c\/td\u003e\n\u003ctd\u003e7.5 ms per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProfinet \/ EtherNet\/IP deterministic networks\u003c\/h3\u003e\n\u003cp\u003eThe module utilizes backplane bus communication velocity to transmit digitized analog data to the host CPU. By maintaining deterministic scan intervals, the module ensures that the 15-bit resolution data is available for PLC logic execution within a consistent 7.5 ms window per channel. The internal circuitry supports firmware flash compatibility, allowing for potential updates to signal filtering algorithms or communication handshaking protocols as necessitated by the broader VersaMax system architecture.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the single-ended input configuration require a common reference point for all signals?\u003c\/p\u003e\n\u003cp\u003eA: Yes, as a single-ended module, all 15 inputs share a common return path. Ensure the reference ground is consistent across the connected field devices to prevent common-mode voltage errors.\u003c\/p\u003e\n\u003cp\u003eQ: Is the 100 kOhm input impedance sufficient for standard process sensors?\u003c\/p\u003e\n\u003cp\u003eA: The 100 kOhm input impedance is high enough to minimize loading effects on most low-voltage signal sources, maintaining measurement accuracy for the -10 VDC to 10 VDC range.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eSecure the module onto a standard VersaMax carrier base. Ensure the mechanical locking tab clicks into place to guarantee backplane pin contact.\u003c\/li\u003e\n\u003cli\u003eShield all incoming signal wiring using twisted-pair cabling. Bond the shield drain wire to the dedicated ground terminal on the carrier or the panel chassis to prevent EMI ingress.\u003c\/li\u003e\n\u003cli\u003eVerify that the input signal voltage does not exceed the +\/- 10 VDC limit, as excessive voltage may lead to permanent component degradation.\u003c\/li\u003e\n\u003cli\u003eRoute signal wires away from high-current power cabling to minimize inductive noise coupling into the sensitive 15-bit input stages.\u003c\/li\u003e\n\u003cli\u003ePerform a system-level calibration check in the PLC software to verify the digital representation matches the analog input value across the full operating range.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"GE FANUC","offers":[{"title":"Default Title","offer_id":52429880557880,"sku":"IC200ALG263F","price":220.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/IC200ALG263.jpg?v=1779155745","url":"https:\/\/www.automodulexpert.com\/products\/ge-fanuc-analog-input-module-ic200alg263f","provider":"AutoModuleXpert Ltd.","version":"1.0","type":"link"}