GE Fanuc HE693PBS105 PROFIBUS DP Slave Network Module

GE Fanuc HE693PBS105 PROFIBUS DP Slave Network Module
GE Fanuc HE693PBS105 PROFIBUS DP Slave Network Module
GE Fanuc HE693PBS105 PROFIBUS DP Slave Network Module
GE Fanuc HE693PBS105 PROFIBUS DP Slave Network Module
GE Fanuc HE693PBS105 PROFIBUS DP Slave Network Module
GE Fanuc HE693PBS105 PROFIBUS DP Slave Network Module

GE Fanuc HE693PBS105 PROFIBUS DP Slave Network Module

This HE693PBS105 PROFIBUS DP Slave Network Module was manufactured by GE FANUC, In Stock, 100% Guaranteed Brand New and Authentic. Link to More Information

 
Manufacturer:
GE FANUC
Part Number:
HE693PBS105
Country of Origin:
USA
Condition:
New With Original Package
Shipping Port:
ShangHai, Xiamen
Warranty:
12 Months
Collections:
 

The GE Fanuc HE693PBS105, also cataloged as the HE693PBS105 PROFIBUS DP Slave Network Module, operates as a dedicated hardware component for high-speed network communication and slave data interchange within Series 90-30 PLC platforms.

Suffix Breakdown & Model Matrix

  • HE693PBS105: Standard rack-mounted PROFIBUS DP slave communication module designed for Series 90-30 backplane integration supporting up to 64 connected devices.

Hardware Specifications

Parameter Specification
Model HE693PBS105
Brand GE Fanuc
Origin USA
Weight 0.18 kg
Dimensions Standard Series 90-30 module form factor
Operating Temp 0 deg C to 60 deg C
Power Consumption Powered by the Series 90-30 PLC backplane
Module Type PROFIBUS DP Slave Network Module
Interface RS-232 serial interface
Supported Devices Up to 64 connected devices
Communication Protocol PROFIBUS DP
Data Rate Up to 12 Mbps

Profinet and Deterministic Network Processing

The internal communication coprocessor executes deterministic protocol handling over the PROFIBUS DP network layer, ensuring time-critical cyclic data exchange across distributed automation nodes. Backplane bus communication velocity parameters allow seamless telegram processing without introducing jitter into the central processing unit's scan cycle. Galvanic isolation circuits protect the serial and network transceivers from common-mode transients and ground potential shifts across industrial loops.

Frequently Asked Questions

Q: Does this module support live hot-swapping within an active Series 90-30 rack?

A: Hot-plugging is restricted; system power must be disconnected from the baseplate prior to inserting or extracting the module to prevent backplane bus errors or connector damage.

Q: What is the maximum baud rate supported by the PROFIBUS slave interface?

A: The module communicates at selectable data rates up to 12 Mbps depending on network topology and cable length parameters.

Q: How is the node address configured for the network interface?

A: Station addresses are typically set using hardware-accessible configuration switches or via programming software during initial PLC configuration.

Field Installation Guidelines

  • Ensure that all rack power is turned off before installing or removing the module from the Series 90-30 baseplate slot.
  • Connect PROFIBUS communication cables using proper shielded twisted-pair media and ensure correct bus termination resistors are active at both physical ends of the trunk line.
  • Route serial and network cabling away from high-voltage power conduits and variable frequency drives to minimize electromagnetic interference.
Quick Quotes Receive price & availability FAST from our dedicated customer service team.
Delivery Expedited, Freight, And International Shipping Available.
Condition 100% New with Original Package
Payment We accept American Express, Discover, MasterCard, PayPal, and Visa. Our site is secured by RapidSSL.
Shipping Port ShangHai, Xiamen
Warranty 12 Months
Q: Is Our Pricing Competitive?
A: Yes, we collaborate with over 50 countries worldwide. As a top supplier in China, we offer significant discounts based on market trends.
Q: What Is the Warranty Period?
A: All our new and original products come with a standard one-year warranty.
Q: What Payment Methods Do We Accept?
A: We require 100% T/T (Telegraphic Transfer) payment before shipping. For items with a lead time, a 30% deposit is needed upfront, and the remaining 70% is due before shipping. If you have a representative in China, you can arrange an RMB transfer through them.
Q: What Shipping Methods Do We Use?
A: We primarily use FedEx, DHL, UPS, and BRE for shipping. If you have an account with any of these carriers, you can handle shipping directly. We also offer free shipping to China-based freight forwarders.
Q: What Is Our Delivery Time?
A: Delivery usually takes 1-3 days after receiving the initial payment. For items with a lead time, shipping will occur according to the specified schedule.
Q: How Do We Package the Goods?
A: We ensure safe packaging with multiple layers of protection. Products are first placed in their original boxes and sealed with labels. A layer of bubble wrap is then added for collision protection during transit. Finally, the items are packed securely in durable boxes.
Q: How Can Customers Contact Us and Request a Quote?
A: You can reach out to us via email, WhatsApp, WeChat, Skype, or your preferred communication platform. Contact us with your needs, and we'll provide a prompt, customized quote.
 

Recently Viewed

Express Shipping icon
Express Shipping
Rapid delivery for your urgent requirements.
Large stock icon
Extensive Inventory
Large stock for immediate dispatch.
Quality Assurance Icon
Quality Assurance
Authentic, top-grade PLC & DCS components.
Global Service icon
Global Service
Supporting clients worldwide with dependable service.