{"product_id":"ge-fanuc-ic695alg600-universal-analog-input-module","title":"GE Fanuc IC695ALG600 Universal Analog Input Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC695ALG600\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ehigh-density universal analog input module\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePACSystems RX3i\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eplatform. It features\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eeight independently configurable channels\u003c\/strong\u003e, organized into two groups of four, and interfaces with various industrial sensors, including voltage, current, resistance,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eThermocouples (TC)\u003c\/strong\u003e, and\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eResistance Temperature Detectors (RTD)\u003c\/strong\u003e. This versatility reduces the need for multiple specialized modules, streamlining spare parts inventory and cabinet space. Guaranteed\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% brand new\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto meet Emerson and\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGE Fanuc automation system standards\u003c\/strong\u003e.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Line\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePACSystems RX3i\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Channels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 Channels (2 groups of 4)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent Inputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0–20 mA, 4–20 mA, ±20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage Inputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±50mV, ±150mV, 0–5V, 1–5V, 0–10V, ±10V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRTD Support\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePT 385\/3916, Ni 618\/672, NiFe 518, CU 426\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResistance Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 4000 Ohms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBackplane Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRX3i Universal Backplane (PCI Bus)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.34 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eUniversal Channel Configuration\u003c\/strong\u003e: Supports simultaneous monitoring of different input types, e.g., a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003epressure transmitter\u003c\/strong\u003e,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eRTD temperature sensor\u003c\/strong\u003e, and\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003emotor voltage\u003c\/strong\u003e, optimizing hardware use.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Resolution Signal Processing\u003c\/strong\u003e: Converts analog signals into precise digital data for the CPU, ensuring accuracy in sensitive applications like\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003echemical dosing\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ethermal processing\u003c\/strong\u003e.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFlexible Termination Options\u003c\/strong\u003e: Supports terminal blocks like\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC694TBB132\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC694TBS132\u003c\/strong\u003e, offering space for shielded cables and thick insulation, ideal for electrically noisy environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eReal-Time Diagnostic LEDs\u003c\/strong\u003e: Three LED indicators (Module, Field, and TB Status) provide instant feedback, allowing technicians to verify power presence and connection integrity without needing a laptop.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e1. What firmware version is required for the IC695ALG600?\u003c\/strong\u003e\u003cbr\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eRX3i CPU\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003erequires\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003efirmware version 2.80 or later\u003c\/strong\u003e. Configuration needs\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eProficy Machine Edition 5.0 SP1A\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ewith the appropriate hotfix.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e2. Do I need to calibrate the module manually?\u003c\/strong\u003e\u003cbr\u003eNo, the module is\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003efactory calibrated\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand performs\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eself-calibration cycles\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eduring operation to maintain accuracy over time and with temperature changes.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e3. Can I upgrade the module features in the future?\u003c\/strong\u003e\u003cbr\u003eYes, it includes\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003einternal flash memory\u003c\/strong\u003e, allowing for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003efield firmware upgrades\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto access new features or performance enhancements.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e4. Which terminal block is best for high-density wiring?\u003c\/strong\u003e\u003cbr\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC694TBB132 (Extended Box-style)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eor\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC694TBS132 (Extended Spring-style)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eare recommended for their ability to handle larger wire bundles and shield terminations typical of\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8-channel analog installations\u003c\/strong\u003e.\u003c\/p\u003e","brand":"GE FANUC","offers":[{"title":"Default Title","offer_id":52136870445368,"sku":"IC695ALG600","price":220.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/IC695ALG6001.jpg?v=1775699696","url":"https:\/\/www.automodulexpert.com\/products\/ge-fanuc-ic695alg600-universal-analog-input-module","provider":"AutoModuleXpert Ltd.","version":"1.0","type":"link"}