{"product_id":"ge-fanuc-ic697cmm711-series-90-70-communication-coprocessor-module","title":"GE Fanuc IC697CMM711 Series 90-70 Communication Coprocessor Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC697CMM711\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ehigh-performance communication coprocessor\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGE Fanuc Series 90-70 PLC system\u003c\/strong\u003e. Equipped with a dedicated\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e12 MHz 80C186 microprocessor\u003c\/strong\u003e, this module offloads communication tasks from the main CPU, ensuring\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003econsistent scan times\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003erapid data exchange\u003c\/strong\u003e. It offers\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003etwo independent 25-pin D-shell serial ports\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esupporting a variety of industrial protocols, including\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eModbus RTU\u003c\/strong\u003e,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSNP\/SNP-X\u003c\/strong\u003e, and\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCCM\u003c\/strong\u003e.\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% brand new\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand packed in original factory condition.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMicroprocessor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12 MHz\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e80C186\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtocols Supported\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eSNP\/SNP-X\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(Master\/Slave),\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCCM\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(Master\/Slave\/Peer),\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eModbus RTU\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(Slave)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterface Ports\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTwo\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e25-pin D-shell connectors\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBaud Rates\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e300 to 19,200 bps\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBackplane Current Draw\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e700 mA @ 5 VDC\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIndicators\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eModule OK\u003c\/strong\u003e,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePort 1 Status\u003c\/strong\u003e,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePort 2 Status\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl Features\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eFront-panel restart pushbutton\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e0.51 kg\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOptimized CPU Performance\u003c\/strong\u003e: The dedicated\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e80C186 processor\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eoffloads serial protocol overhead, enabling the main PLC CPU to focus entirely on logic execution. This ensures\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003efaster response times\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ewithout communication delays.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVersatile Protocol Combinations\u003c\/strong\u003e: The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003etwo independent ports\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ecan be configured for different protocols. For example, you can run\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSNP on Port 1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor an HMI and\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eModbus RTU on Port 2\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor data collection, providing a flexible gateway between multiple networks.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSoftware-Defined Configuration\u003c\/strong\u003e: There are\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eno physical jumpers or DIP switch settings\u003c\/strong\u003e. All baud rate and protocol parameters are managed via software (Proficy Machine Edition or Logicmaster 90-70), simplifying setup and troubleshooting.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEnhanced System Diagnostics\u003c\/strong\u003e: The module includes\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ethree LED indicators\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor immediate feedback on module health and active port traffic. If issues arise, the integrated\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003epushbutton\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eallows for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003equick module re-initialization\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ewithout powering down the entire PLC.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e1. Does this module require a battery for program storage?\u003c\/strong\u003e\u003cbr\u003eNo, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC697CMM711\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edoes not need a battery. Configuration is received directly from the CPU module during power-up.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e2. Can this module act as a Modbus Master?\u003c\/strong\u003e\u003cbr\u003eNo, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC697CMM711\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esupports\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eModbus RTU in Slave mode\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eonly. For Modbus Master functionality, you’ll need a different module or a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eC-Programmable\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emodule.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e3. What cable is needed for the 25-pin ports?\u003c\/strong\u003e\u003cbr\u003eThe module uses\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eRS-232\u003c\/strong\u003e,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eRS-422\u003c\/strong\u003e, or\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eRS-485\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ephysical layers, depending on your configuration. Use\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eshielded cables\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ewith\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e25-pin D-shell connectors\u003c\/strong\u003e, wired according to your chosen protocol and interface type.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e4. Is it safe to install this module while the PLC is powered?\u003c\/strong\u003e\u003cbr\u003eNo,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003epower must be removed\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efrom the baseplate before installing or removing the module. Inserting the module into a live backplane can cause\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eelectrical arcing\u003c\/strong\u003e, damaging the coprocessor and adjacent modules.\u003c\/p\u003e","brand":"GE FANUC","offers":[{"title":"Default Title","offer_id":52137091957048,"sku":"IC697CMM711","price":220.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/IC697CMM7112.jpg?v=1775699696","url":"https:\/\/www.automodulexpert.com\/products\/ge-fanuc-ic697cmm711-series-90-70-communication-coprocessor-module","provider":"AutoModuleXpert Ltd.","version":"1.0","type":"link"}