{"product_id":"ge-fanuc-ic697mdl650-discrete-input-module","title":"GE Fanuc IC697MDL650 Discrete Input Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC697MDL650\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ehigh-density discrete input module\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGE Fanuc Series 90-70 PLC\u003c\/strong\u003e. It provides\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e32 input points\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor interfacing with 24 VDC\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eproximity switches\u003c\/strong\u003e,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003epushbuttons\u003c\/strong\u003e, and\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003elimit switches\u003c\/strong\u003e. The module converts field-level signals into digital data for the controller, ensuring seamless communication between sensors and the CPU logic.\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% brand new\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand packaged in original factory condition.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"\"\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth class=\"\"\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e24 VDC\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(Positive\/Negative Logic)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Inputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e32 Points\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Voltage Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e0 to +30 VDC\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e7.0 mA\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(typical) at 24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOn-State Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e14 to 30 VDC\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOff-State Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e0 to 5 VDC\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Filter Delay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e1 ms to 2 ms\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInternal Power Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e0.45 Amps\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efrom 5V bus (typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBackplane Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eIC697 Standard VME Rack\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Density Signal Management\u003c\/strong\u003e: Houses\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e32 inputs\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ein a single slot, reducing the PLC rack footprint and hardware costs for systems with high I\/O counts.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFlexible Wiring Logic\u003c\/strong\u003e: Supports\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003esink\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003esource\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ewiring configurations, making it easy to integrate various sensors without additional interface relays.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRapid Signal Detection\u003c\/strong\u003e: High-speed\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003einput filter\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003estabilizes signals in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1 to 2 milliseconds\u003c\/strong\u003e, ensuring fast response in dynamic manufacturing environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSimplified Maintenance Access\u003c\/strong\u003e:\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFront-panel LED indicators\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprovide real-time status for each input, making it easy to identify sensor issues or wiring breaks.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e1. Does this module require a specific terminal block?\u003c\/strong\u003e\u003cbr\u003eYes, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC697MDL650\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003euses a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eremovable front terminal block\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ethat supports up to 32 points of field wiring, allowing easy module replacement without disturbing existing cables.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e2. How do I configure the input logic for Sink vs. Source?\u003c\/strong\u003e\u003cbr\u003eThe module's logic is determined by how you wire the common terminals.\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eNegative rail to common\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e=\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003epositive logic (source)\u003c\/strong\u003e, and\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003epositive rail to common\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e=\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003enegative logic (sink)\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e3. Can I use this module with 5V or 12V DC signals?\u003c\/strong\u003e\u003cbr\u003eNo, this module requires at least\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e14 VDC\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor an \"ON\" state. For lower voltages, select a different\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC697 input module\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003erated for those levels.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e4. Is there internal fuse protection for the inputs?\u003c\/strong\u003e\u003cbr\u003eNo, the module lacks internal fuses. It is recommended to install\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eexternal fusing\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor protection against wiring shorts in the field power supply.\u003c\/p\u003e","brand":"GE FANUC","offers":[{"title":"Default Title","offer_id":52137050243384,"sku":"IC697MDL650","price":220.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/IC697MDL650.jpg?v=1775699696","url":"https:\/\/www.automodulexpert.com\/products\/ge-fanuc-ic697mdl650-discrete-input-module","provider":"AutoModuleXpert Ltd.","version":"1.0","type":"link"}