{"product_id":"ge-fanuc-ic698psd300-pacsystems-rx7i-power-supply-module","title":"GE Fanuc IC698PSD300 PACSystems RX7i Power Supply Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eGE Fanuc IC698PSD300 delivers 300 watts of regulated power to the PACSystems RX7i backplane. It accepts 24 VDC input (18–30 VDC range) and mounts exclusively in Slot 0. The module supplies +5 VDC, +12 VDC, and -12 VDC to CPUs, I\/O, and communication modules while managing logic-level sequencing for controlled power-up and shutdown cycles.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003e\n\u003cp\u003eParameter\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth\u003e\n\u003cp\u003eSpecification\u003c\/p\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eManufacturer\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eGE Fanuc\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eModel\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eIC698PSD300\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eRated Power\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e300 Watts (Max Total Output)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eInput Voltage\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e24 VDC Nominal (18 – 30 VDC Range)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eOutput Voltages\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e+5 VDC @ 50A, +12 VDC @ 10A, -12 VDC @ 4A\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eInrush Current\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 Amps Maximum (Cold Start)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eIsolation\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e250 VAC Continuous; 1500 VAC for 1 Minute\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eOperating Temperature\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e0°C to 60°C (32°F to 140°F)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eHoldup Time\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e5 ms Minimum\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eRide-Through Time\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e15 ms Minimum (Loss of Input Power)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eMounting Location\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eSlot 0 (Leftmost Slot of RX7i Rack)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cp\u003eThe IC698PSD300 eliminates power instability risks in high-density automation racks. It requires\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e70 CFM forced-air cooling\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto sustain full 300W output; insufficient airflow triggers automatic derating or thermal shutdown. An onboard airflow sensor immediately cuts outputs and lights the RED OVER TEMP LED upon detecting cooling failure or overheating. Integrated diagnostics monitor overcurrent, overvoltage, and short circuits, displaying real-time status via front-panel LEDs (OUTPUT OK, OVER TEMP, POWER FAIL) for rapid on-site troubleshooting—no rack disassembly required. This safeguards continuous operation against voltage transients and thermal stress in mission-critical process control systems.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCan I install the IC698PSD300 in any slot other than Slot 0?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. RX7i architecture mandates Slot 0 occupancy for power distribution and sequencing signal transmission; installation elsewhere disables rack operation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat happens if forced-air cooling fails?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe airflow sensor detects cooling loss instantly. The module shuts down all outputs and illuminates the Over Temp LED to prevent hardware damage, resuming operation only after cooling restores and temperatures normalize.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs this module compatible with Series 90-70 expansion racks?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The IC698PSD300 interfaces exclusively with PACSystems RX7i main racks and does not support Series 90-70 expansion configurations.\u003c\/p\u003e","brand":"GE FANUC","offers":[{"title":"Default Title","offer_id":52371702284600,"sku":"IC698PSD300","price":220.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0893\/1616\/3896\/files\/IC698PSD300.jpg?v=1778812152","url":"https:\/\/www.automodulexpert.com\/products\/ge-fanuc-ic698psd300-pacsystems-rx7i-power-supply-module","provider":"AutoModuleXpert Ltd.","version":"1.0","type":"link"}